in energy chains or mobile machine parts, use in measuring, control and regulation circuits, plant engineering, machine tools, assembly lines, production lines, in all types of machines, multi-standard validation reduces the variety of parts and saves costs, can also be used outdoors if the temperature range is observed, ideal for export-oriented machine and equipment builders, extra-fine-wire strand made of bare copper wires (class 6), core insulation: PVC, cores stranded in layers with short lay lengths, fleece wrapping, PVC sheath, black (RAL 9005), when used in energy chains: please note assembly guidelines appendix T3, UL AWM Style 21098, CSA AWM IA/B, IIA/B FT 1, UL File No. E63634, oil-resistant, low-adhesion surface, flame-retardant in accordance with IEC 60332-1-2 & CSA FT1, designed for 5 million alternating bending cycles and travel distances of up to 10 meters,
| Property | Value |
| Number of cores: | 4 |
| Conductor nominal cross-section: | 1.5 mm² |
| Sheath color: | black |
| Outer diameter approx.: | 8.8 mm |
| Conductor class: | Cl.6 = extra-fine-wire |
| Stranding element: | no |
| Material of the core insulation: | Polyvinyl chloride (PVC) |
| Core marking: | numbers |
| Protective conductor: | yes |
| Shield over stranding element: | without |
| Shield over stranding: | without |
| Support element: | without |
| Sheath material: | Polyvinyl chloride (PVC) |
| Torsion protection: | no |
| Halogen-free according to EN 60754-1/2: | no |
| Flame-retardant: | according to EN 60332-1-2 |
| Low smoke according to EN 61034-2: | no |
| Cold-resistant according to EN 60811-504+505+506: | yes |
| Oil-resistant according to EN 60811-404: | yes |
| Permissible external cable temperature during assembly/handling: | -5 to 70 °C |
| Permissible Cable external temperature after installation without vibration: | -40 to 70 °C |
| Nominal voltage U0: | 300 V |
| Nominal voltage U: | 500 V |
| AWG size: | 16 |
| Conductor nominal cross-section (AWG): | 16 kcmil |
| Specification of core insulation: | other |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | without |
| Smoke development class according to EN 13501-6: | without |
| Drip behavior class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Shape: | round |
| Min. permissible bending radius, flexible use with forced guidance: | 66 mm |
| Min. permissible bending radius, stationary use/fixed installation: | 35.2 mm |