Space-saving due to small cable diameters, High electrical safety due to 4 kV test voltage., Areas of application, Plant engineering, Mechanical engineering, Heating and air conditioning technology, Power plant technology, Event technology, Fixed installation as well as occasional flexible use without tensile stress with free, not constantly recurring movement, Dry or damp rooms, with normal mechanical stress, Benefits, Space-saving due to small cable diameters, High electrical safety due to 4 kV test voltage, Structure, Fine-wire strand made of bare copper wires, PVC core insulation LAPP P8/1, Cores twisted in layers, PVC jacket, grey (RAL 7001), Standard references, Product properties, Flame-retardant according to IEC 60332-1-2, Technical data, Core identification code, Black with white numbers according to 0293, Insulation Specific volume resistance, >, 20 GOhm x cm, Conductor structure, Fine-wire according to 0295, Class 5 / IEC 60228, Cl.5, Minimum bending radius, Occasional moving: 15 x outer diameter, Fixed installation: 4 x outer diameter, Nominal voltage, U0/U: 300/500 V, Test voltage, 4000 V, Protective conductor, G = with protective conductor GN/GE, X = without protective conductor, Temperature range, Occasional moving: -5°C to +70°C, Fixed installation: -40°C to +80°C, VDE-tested, Reg. No. 7030 for the following dimensions: up to 2.5 mm²: 2 - 65 cores from 4 mm²: 2 - 7 cores
Property | Value |
Number of cores: | 4 |
Conductor nominal cross section: | 0.5 mm² |
Sheath color: | gray |
5.7 mm | |
Conductor class: | Kl.5 = finely stranded |
Stranding element: | no |
Material of the core insulation: | Polyvinyl chloride (PVC) |
Core identification: | Numbers |
Protective conductor: | no |
Shield over Stranding element: | without |
Shield over stranding: | without |
Support element: | without |
Sheath material: | Polyvinyl chloride (PVC) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | according to EN 6033 2-1-2 |
Low smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil resistant according to EN 60811-404: | no |
Permissible external cable temperature during assembly/handling: | -15 to 70 °C |
Permissible external cable temperature during assembly/handling: External cable temperature after installation without vibration: | -40 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
Shape: | round |
Min. permissible bending radius, flexible use with forced guidance: | 85.5 mm |
Min. permissible bending radius, flexible use/free movement: | 57 mm |
Min. permissible bending radius, stationary use/fixed installation: | 22.8 mm |