For the wiring or connection of lights, heating devices, switchgear and distributors in mechanical, plant and equipment construction, For laying in pipes, on, in and under plaster as well as in closed installation ducts, winding goods, (electro)magnets, pumps, electrical systems, heat treatment systems, die casting technology, heating and cooling technology, For assembling cable harnesses and for wiring during switch cabinet installation, Safety in areas with high concentrations of people, Reduction of fire spread, smoke gas density and their toxicity in the event of a fire, Minimization of consequential fire damage to buildings and equipment due to toxic acid formation, Certified for maritime use, Fine-wire, tinned copper conductor, Insulation made of electron beam cross-linked polyolefin copolymer, Type H05Z-K and H07Z-K in accordance with EN 50525-3-41 with extended properties, Germanischer Lloyd (GL) Certificate No. 11118-14HH, Fire behaviour: - Flame retardancy (IEC 60332-1-2) - Halogen-free (IEC 60754-1) - Corrosiveness of gases (IEC 60754-2) - Smoke density (IEC 61034-2) - Low toxicity (EN 50305), UV-resistant according to ISO 4892-2, Abrasion-resistant and notch-resistant, Extended fire behaviour: H05Z-K (0.5mm² to 1.0mm²): see data sheet H07Z-K (1.5mm²): no fire propagation according to IEC 60332-3-24 or IEC 60332-3-25, Oil-resistant according to DIN EN 50290-2-22 (TM54),
| Property | Value |
| Number of cores: | 1 |
| Conductor nominal cross-section: | 16 mm² |
| Core color: | green/yellow |
| Outer diameter approx.: | 7.2 mm |
| Core marking: | Color |
| Core insulation material: | Polyolefins |
| Sheath color: | without |
| Sheath material: | without |
| Protective conductor: | yes |
| Nominal voltage U0: | 750 V |
| Nominal voltage U: | 750 V |
| Conductor material: | copper |
| Conductor class: | Class 5 = finely stranded |
| Perm. max. conductor temperature: | 125 °C |
| Shield: | no |
| Drain wire: | no |
| Protective cover: | without |
| Reinforcement/armoring: | without |
| Halogen-free according to EN 60754-1/2: | yes |
| Flame-retardant: | according to EN 60332-3-24 |
| Low smoke according to EN 61034-2: | yes |
| Cold-resistant according to EN 60811-504+505+506: | yes |
| Oil-resistant according to EN 60811-404: | yes |
| Insulation integrity: | no |
| Permissible external cable temperature during assembly/handling: | -35 to 125 °C |
| Permissible Cable external temperature after installation without vibration: | -55 to 125 °C |
| Conductor surface: | tinned |
| AWG size: | 6 |
| Conductor nominal cross-section (AWG): | 6 kcmil |
| Wires twisted: | no |
| Wire insulation specification: | other |
| Fire behavior class according to EN 13501-6: | Eca |
| Smoke development class according to EN 13501-6: | without |
| Drip behaviour class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Min. permissible bending radius, stationary use/permanently installed: | 28.8 mm |