Food and packaging machines, industrial and machine tools, measuring, control and electrical engineering, Can also be used outdoors when the temperature range is observed, In oily wet areas of machine tools and transfer lines, under normal mechanical stress, Durable under rough use due to resistant PUR sheath material, Insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, Copper braid to comply with EMC and shield against electromagnetic interference fields, Additional robustness due to inner sheath, Compatible with many acidic disinfectants and cleaning agents, Fine-wire, bare copper conductor, Core insulation: special PVC, PVC inner sheath, grey, Cores twisted in layers, Copper braid, tinned, Sheath made of special polyurethane (PUR), Sheath colour: grey (similar to RAL 7001), Based on 0285, Certified resistance to disinfectants and Cleaning agents from the food and beverage industry, Increased oil resistance, Abrasion resistant and notch tough, Low-adhesion surface, EMC compliant, Hydrolysis resistant and microbe resistant,
Property | Value |
Number of cores: | 25 |
Nominal conductor cross-section: | 1.5 mm² |
Sheath color: | gray |
Outer diameter approx.: | 20.1 mm |
Conductor class: | Class 5 = fine-wire |
Stranding element: | no |
Material of the core insulation: | Polyvinyl chloride (PVC) |
Core marking: | numbers |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over stranding: | braid |
Support element: | without |
Sheath material: | Polyurethane (PUR) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | no |
Low-smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | no |
Perm. External cable temperature during assembly/handling: | -5 to 70 °C |
Perm. Cable external temperature after installation without vibration: | -40 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 16 |
Conductor nominal cross-section (AWG): | 16 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Drip behavior class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Shape: | round |
Min. permissible bending radius, flexible use/free movement: | 402 mm |
Min. permissible bending radius, stationary use/fixed installation: | 120.6 mm |