Communication at the sensor/actuator level, fixed installation as well as occasional flexible use without tensile stress with free, non-constantly recurring movement, the TPE version has an oil-resistant outer jacket. It is suitable for wet areas, especially in conjunction with water-miscible cooling lubricants., Sensor/actuator cabling, with the new BUS ASI LD 2x2.5 (Long Distance) modules that are further away can now also be connected. Additional AS-I power supplies can be saved. BUS ASI LD is downwards compatible with the 1.5 version., the rubber variants are halogen-free, fine-wire tinned copper strands, core insulation (blue and brown), profiled outer jacket made of rubber (G), or thermoplastic elastomer (TPE), or PVC, color: yellow (RAL 1023) or black (RAL 9005), color: red (RAL 3000), ASI is standardized in EN 50295 Europe-wide and IEC 62026-2 internationally, PVC version with UL/CSA (CMX) validation, UL/CSA version: CMG c (UL) us or (UL) CL2 or AWM 300V FT4 validated, data and energy are transmitted via unshielded, geometrically coded two-wire flat cable (polarity reversal protected)., Contacting of the conductor is done via Penetration technology in the ASI modules., The sensors are connected to the ASI modules (coupling modules) using round cables (connecting cables).,
Property | Value |
Number of cores: | 2 |
Conductor class: | Class 5 = fine-wire |
Stranding element: | other |
Core marking: | Color |
Shield over stranding element: | without |
Category: | without |
Flame retardant: | no |
Low smoke according to EN 61034-2: | no |
Sheath color: | black |
Conductor diameter: | 1.5 mm |
Stranding: | other |
Material of core insulation: | rubber |
Shielding over stranding: | without |
Conductor surface: | tinned |
Protective jacket: | no |
Reinforcement: | no |
Jacket material: | rubber |
Halogen-free according to EN 60754-1/2: | no |
Halogen-free according to IEC 60754-2: | no |
Low smoke according to IEC 61034-2: | no |
Oil resistant according to EN 60811-404: | no |
Oil resistant according to IEC 60811-404: | no |
Insulation integrity according to IEC 60331: | no |
Functional integrity: | no |
Specification of core insulation: | other |
Cable longitudinally watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Dripping behaviour class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Min. permissible bending radius, stationary use/permanently installed: | 12 mm |
Laying in the ground: | no |
UV-resistant: | yes |