PROFIBUS DP (according to DIN 19245 and EN 50170, e.g. for SIEMENS SIMATIC® NET, also for FIP Factory Instrumentation Protocol)., Cables can be used for PROFIBUS-DP, PROFIBUS-FMS as well as FIP, Use wherever the combination of an outer sheath with properties similar to polyurethane, freedom from halogens and increased flame retardancy is required, Bare copper strand, Core insulation: PE, Overall shielding with copper braid and plastic-laminated aluminum foil, Outer sheath: PUR, violet (RAL 4001), Validation: UL Type CMX according to UL 444, TORSION: for torsional stress, e.g. B. Robot application, ± 180° per 1m, Halogen-free, Flame-retardant according to IEC 60332-1-2, At the listed bit rates, the following maximum cable length of a bus segment (cable type A, PROFIBUS-DP) results according to PNO specifications: 93.75 kbit/s = 1200 m 187.5 kbit/s = 1000 m 500 kbit/s = 400 m 1.5 Mbit/s = 200 m 12.0 Mbit/s = 100 m,
| Property | Value |
| Number of cores: | 2 |
| Outer diameter approx.: | 8 mm |
| Conductor class: | Cl.6 = extra fine wire |
| Stranding element: | other |
| Core marking: | Color |
| Shield over stranding element: | Foil + braid |
| Category: | without |
| Flame-retardant: | according to IEC 60332-1-2 |
| Low smoke according to EN 61034-2: | no |
| Sheath color: | other |
| Conductor nominal cross-section: | 0.38 mm² |
| Stranding: | bundle |
| Material of the conductor insulation: | polyolefins |
| Number of stranding elements: | 2 |
| Shield over stranding: | foil + braid |
| Conductor surface: | bare |
| Protective sheath: | no |
| Reinforcement: | no |
| Sheath material: | Polyurethane (PUR) |
| Halogen-free according to EN 60754-1/2: | no |
| Halogen-free according to IEC 60754-2: | no |
| Low smoke according to IEC 61034-2: | no |
| Oil-resistant according to EN 60811-404: | no |
| Oil-resistant according to IEC 60811-404: | no |
| Insulation integrity according to IEC 60331: | no |
| Functional integrity: | no |
| NVP value: | 81 % |
| Specification of core insulation: | Polyethylene (PE) |
| Cable longitudinally watertight: | no |
| Cable transversely watertight: | no |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | without |
| Smoke development class according to EN 13501-6: | without |
| Dripping behavior class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Min. permissible bending radius, stationary use/permanently installed: | 32 mm |
| Laying in the ground: | no |
| UV-resistant: | no |