PROFIBUS DP (according to DIN 19245 and EN 50170, e.g. for SIEMENS SIMATIC® NET, also for FIP Factory Instrumentation Protocol)., suitable for torsion applications that are typical in the loop of wind turbines (WKA), cables can be used for PROFIBUS-DP, PROFIBUS-FMS as well as FIP, used wherever the combination of outer jacket with properties similar to polyurethane, halogen-free and increased flame retardancy is required, for highly flexible applications (drag chains, frequently moving machine parts), foam skin - wire insulation (O2YS), bare copper strand, overall shielding with copper braid and plastic-coated aluminum foil, shielding braid made of tinned copper wires, outer jacket: polyurethane (PUR) mixture, validation: UL/CSA type CMX according to UL 444 and CSA C22.2 No.214, flame retardant according to IEC 60332-1-2, halogen-free, For the bit rates listed, the following maximum cable length of a bus segment (cable type A, PROFIBUS-DP) results according to PNO specifications: 93.75 kbit/s = 1200 m 187.5 kbit/s = 1000 m 500 kbit/s = 400 m 1.5 Mbit/s = 200 m 12.0 Mbit/s = 100 m, Oil-resistant,
| Property | Value |
| Number of cores: | 2 |
| AWG cross-section: | 24 |
| Conductor class: | Cl.5 = fine-wire |
| Stranding element: | other |
| Core marking: | Color |
| Shield over stranding element: | without |
| Category: | without |
| Flame-retardant: | according to IEC 60332-1-2 |
| Low smoke according to EN 61034-2: | no |
| Sheath color: | other |
| Stranding: | other |
| Material of the core insulation: | other |
| Number of stranding elements: | 1 |
| Shield over stranding: | Foil + braid |
| Conductor surface: | bare |
| Protective jacket: | no |
| Reinforcement: | no |
| Jacket material: | Polyurethane (PUR) |
| Halogen-free according to EN 60754-1/2: | no |
| Halogen-free according to IEC 60754-2: | no |
| Low smoke according to IEC 61034-2: | no |
| Oil-resistant according to EN 60811-404: | no |
| Oil-resistant according to IEC 60811-404: | no |
| Insulation integrity according to IEC 60331: | no |
| Functional integrity: | no |
| Permissible external cable temperature during assembly/handling: | -40 to 75 °C |
| Permissible Cable external temperature after installation without vibration: | -40 to 80 °C |
| Specification of core insulation: | Polyethylene (PE) |
| Cable longitudinally watertight: | no |
| Cable transversely watertight: | no |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | none |
| Smoke development class according to EN 13501-6: | none |
| Drip behaviour class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Min. permissible bending radius, flexible use/free movement: | 65 mm |
| Laying in the ground: | no |
| UV-resistant: | no |