+351 934 234 451‬
Leave a call order
Адрес:
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Schedule:
Get route

Legrand 415958 Fire protection switch DX3 AFDD B16 1P+NR 10KA 30MA A FI/LS

Brand:Legrand
SKU:409825
Legrand 415958 Fire protection switch DX3 AFDD B16 1P+NR 10KA 30MA A FI/LS
Insert Module Type
Manufacturer
HAN
GTIN
In stock
€115
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description

Legrand fire protection switch DX3 STOP ARC. According to EN 62606,0665-10, EN 61009-1,0664-20. AFDD with FI/LS switch, 1-pole with switching neutral conductor, type A for alternating and pulsating direct residual currents, undelayed, rated residual current Idn 30 mA, surge current resistant up to 250 A. LS circuit breaker part: B characteristic, rated current In 16 A, rated switching capacity Icn 10 kA in accordance with EN 61009-1, rated voltage Un 230 VAC, rated frequency 50 Hz, energy limitation class 3, fastening on top hat rail EN 60715 using snap-in fastenings, clear information on the front of each device, clear switch position indicator red/green on the switch lever, with label window, neutral conductor connection on the right, can be mounted using Legrand fork comb rails. Auxiliary devices can be attached. Tripping indicator: yellow = residual current or test button tripping, colorless = short circuit or manual tripping. The DX3 STOP ARC fire protection switch is a device combination of an arc fault protection device (AFDD) with a residual current circuit breaker and a miniature circuit breaker. The single-pole protected and double-pole switched AFDD with FI/LS switch offers a safe all-pole shutdown in the event of the following faults: residual current to earth, overload, short circuit, parallel and serial arc faults. With LED status display for detecting the operating status, signal display for visual detection when an arc fault is triggered. The AFDD unit monitors itself using an internal daily self-test. Causes of arc faults include: Damaged conductor insulation caused by nails, screws or holes, crushed cables or lines, loose or faulty terminals in sockets or screw connections.

Property Value
Rated current: 16 A
Number of poles: 2
Tripping characteristics: B
Rated residual current: 0.03 A
Rated voltage: 230 V
Frequency: 50 Hz
Width in modular spacing: 3
Energy limitation class: 3
Residual current type: A
Switching neutral conductor: yes
Protection class (IP): IP20
Control voltage type additional device: AC
Overvoltage category: 3
Pollution degree: 2
Additional equipment fitted at the factory: other
Rated breaking capacity according to EN 61009: 10 kA
Features
Insert Module Type
Manufacturer
HAN
GTIN
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated residual current
Rated voltage
Rated current
Width in pitch units
Energy limitation class
Residual current type
Frequency
Switching neutral conductor
Number of poles
IP protection)
Degree of contamination
Overvoltage category
Reviews
No reviews yet — your comment may be first.
All reviews 0
general rating