Description
Features
Reviews
Photoelectric sensor, M18, axial, metal housing, red LED, through beam, 20 m, NPN, L-ON/D-ON selectable, 2 m cable
Property | Value |
Range of the protective field: | 20 m |
Design of the switching output: | NPN |
Rated switching distance: | 20000 mm |
Rated control supply voltage Us at DC: | 10 to 30 V |
Max. Output current: | 100 mA |
Button function: | light/dark switching |
Protection class (IP): | IP67 |
Length of sensor: | 44 mm |
Diameter of sensor: | 18 mm |
Design of interface for safety-related communication: | other |
Explosion protection category for gas: | without |
Design of electrical connection: | cable axial |
Laser protection class: | without |
With communication interface INTERBUS: | no |
With communication interface RS-485: | no |
With communication interface Ethernet: | no |
Reflector included in delivery: | no |
Analog output 4 mA ... 20 mA: | no |
Housing design: | Cylinder, thread |
AWG number: | 26 |
With communication interface SSD: | no |
Pre-failure message: | no |
With communication interface CANOpen: | no |
With restart lock: | no |
Analog output -10 V ... +10 V: | no |
Housing material: | metal |
Analog output 0 V ... 10 V: | no |
Light type: | Red light unpolarized |
With analog communication interface: | no |
With PROFIBUS communication interface: | no |
Switching function design: | Normally open (NO) |
Safety type according to IEC 61496-1: | 1 |
Explosion protection category for dust: | without |
Opening angle: | 2 ° |
Material of the optical surface: | Plastic |
Suitable for safety functions: | no |
Analog output 0 mA ... 20 mA: | no |
Wavelength of the sensor: | 624 nm |
Equipment protection class: | Protection class 0 |
With communication interface RS-422: | no |
Max. Switching distance: | 20000 mm |
Switching frequency: | 1000 Hz |
With communication interface AS-Interface: | no |
Response time: | 0.5 ms |
With other analog output: | no |
With monitoring function of downstream devices: | no |
Scope of delivery of the one-way system: | Transmitter and receiver |
With communication interface RS-232: | no |
Number of semiconductor outputs with signaling function: | 1 |
With communication interface SSI: | no |
With communication interface DeviceNet: | no |
Cable sheath material: | Polyvinyl chloride (PVC) |
Ambient temperature: | -25 to 55 °C |
Setting method: | manual setting |
Type of voltage: | DC |
With Time function: | no |
Protection class (NEMA): | other |
Features
Diameter of the sensor
18 mm
Design of the switching function
Normally open (NO)
Switching frequency
1000 Hz
HAB
E3FB-TN11 2M OMI
Manufacturer
HAN
378890
GTIN
4548583440975
Design of the interface for safety-related communication
Other
Design of the switching output
NPN
Design of the electrical connection
Cable axial
Rated control supply voltage Us at DC
10 to 30 V
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Housing design
Cylinder, thread
Length of the sensor
44 mm
IP protection)
IP67
Protection class (NEMA)
Other
Voltage type
DC
Ambient temperature
-25 to 55 °C
Housing material
Metal