Description
8 analog input channels for connecting temperature measuring resistors (RTD). Linear inputs 500 and 5 kΩ. Connection of sensors in 2-, 3- and 4-wire technology. Integrated, digital sensor linearization. Standardized measured value display directly in °C, °F or . Measured value display in 16-bit format or in floating point format. Programmable filters. Short-circuit protected inputs. Stored device nameplate.
Property | Value |
Protection class (IP): | IP20 |
Type of supply voltage: | DC |
Height: | 126.54 mm |
Width: | 53.6 mm |
Depth: | 52.7 mm |
Input, current: | no |
Input, voltage: | no |
Output, current: | no |
Output, voltage: | no |
Supports protocol for SafetyBUS p: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for KNX: | no |
Supply voltage for DC: | 19.2 to 30 V |
Supports protocol for MODBUS: | no |
Supports protocol for PROFIsafe: | no |
Wall/direct mounting possible: | no |
Supports protocol for EtherNet/IP: | no |
Front mounting possible: | no |
Supports protocol for TCP/IP: | no |
Design of the electrical connection: | other |
Rack mounting possible: | no |
Supports protocol for SUCONET: | no |
Resolution of the analog inputs: | 24 bit |
Supports protocol for INTERBUS: | no |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for PROFIBUS: | no |
Suitable for safety functions: | no |
Supports protocol for CAN: | no |
Supports protocol for SERCOS: | no |
IO-Link Master: | no |
Supports protocol for ASI: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFINET CBA: | no |
Supports protocol for Data-Highway: | no |
Supports protocol for other bus systems: | yes |
Input, resistance: | yes |
Input, resistance thermometer: | yes |
Input, thermocouple: | no |
Input signal configurable: | no |
Output signal configurable: | no |
Mounting rail possible: | yes |
Field bus connection via separate bus coupler possible: | yes |
Supports protocol for LON: | no |
Supports protocol for INTERBUS-Safety: | no |
System component: | yes |
Number of other HW interfaces: | 2 |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Analog inputs configurable: | no |
SIL according to IEC 61508: | without |
Analog outputs configurable: | no |
Features
Type of voltage of the supply voltage
DC
Supports protocol for KNX
No
HAB
AXL F RTD8 1F
Manufacturer
HAN
2688077
GTIN
4046356501453
Design of the electrical connection
Other
Width
53.6 mm
Suitable for security functions
No
Height
126.54 mm
SIL according to IEC 61508
Without
IP protection)
IP20
Depth
52.7 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
Yes
Reviews
No reviews yet — your comment may be first.
All reviews 0