According to new requirements: Standard EN 61243-3:2014, single-pole phase test, two-pole rotary field direction indicator, FI/RCD test using two buttons (switchable load), display of voltages also possible without batteries, unscrewable 4 mm test probe adapter, measurement category: CAT IV 1000 V (measurement also for hybrid and electric vehicles and photovoltaic systems), nominal voltage range: 6...1000 V AC / 6.1400 V DC, impedance: 625 kOhm at ELV alternating voltage, continuity test: 0 - 200 kOhm (optical), resistance test: 10, 0...199.9 kOhm, 0-10 kOhm, operating temperature: -15 to +45 °C, protection class II, protection type: IP65, incl. batteries (2x 1.5 V type AAA Micro)
Property | Value |
Voltage display: | LED |
Rotation direction display: | yes |
Power supply: | Battery |
Measuring circuit category: | CAT IV |