Schneider Electric 18661 circuit breaker

To compare
To favorites
SKU:699088
Schneider Electric 18661 circuit breaker
Flush-mounted installation
HAB
Manufacturer
HAN
In stock
€573.34
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Circuit breaker NG125N, 4P, 125A, C-characteristic. Product range: NG125 - Range: Acti 9 - Product or component type: Circuit breaker - Device short name: NG125N - Network type: AC, DC - Trip unit technology: thermomagnetic - Interrupting capacity: 10 kA Icu according to EN/IEC 60947-2 - 500V AC 50/60 Hz, 20 kA Icu according to EN/IEC 60947-2 - 500V DC, 20 kA Icu according to EN/IEC 60947-2 - 440V AC 50/60 Hz, 25 kA Icu according to EN/IEC 60947-2 - 380-415V AC 50/60 Hz, 50 kA Icu according to EN/IEC 60947-2 - 220-240V AC 50/60 Hz.

Property Value
Tripping characteristic: C
Rated current: 125.0 A
Rated voltage: 400.0 V
Type of voltage: AC/DC
Frequency: 50.0 to 60.0 Hz
TE: 6.0
Number of poles (total): 4.0
Additional equipment possible: yes
Overvoltage category: 4.0
Installation depth: 47.0 mm
Protection class (IP): IP20
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 50.0 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 25.0 kA
Pollution level: 3.0
Switching neutral conductor: yes
Number of protected poles: 4.0
Flush-mounted installation: no
Rated insulation voltage Ui: 690.0 V
Rated impulse withstand voltage Uimp: 8.0 kV
Ambient temperature during operation: -30.0 to 70.0 °C
Connectable conductor cross-section, stranded: 10.0 to 50.0 mm²
Connectable conductor cross-section, single-wire: 16.0 to 70.0 mm²
Explosion-proof: no
Features
Flush-mounted installation
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icu according to IEC 60947-2 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 400 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Installation depth
Explosion-proof
Frequency
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
TE
Ambient temperature during operation
Degree of contamination
Additional equipment possible
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating