Cast-enclosed disconnector Interpact INS1600, 4p, 1600A. Series: Compact - Product name: INS1600 - Product or component type: Load break switch - Description of poles: 4P - Network connection: DC, AC - Network frequency: 50/60 Hz - Rated operating current Ie: AC-22A : 1250 A AC 50/60 Hz 480 V NEMA, DC-22A : 1600 A DC 250 V 4 poles in series, AC-22A : 1450 A AC 50/60 Hz 220/240 V, AC-22B : 1600 A AC 50/60 Hz 500/525 V, AC-21B : 1600 A AC 50/60 Hz 220/240 V, AC-21A : 1250 A AC 50/60 Hz 500/525 V, AC-21A : 1250 A AC 50/60 Hz 660/690 V, AC-23A : 1250 A AC 50/60 Hz 380/415 V, AC-22A : 1450 A AC 50/60 Hz 380/415 V, AC-23A : 1250 A AC 50/60 Hz 660/690 V, AC-22B : 1600 A AC 50/60 Hz 220/240 V, AC-22B : 1600 A AC 50/60 Hz 440/480 V, AC-21B : 1600 A AC 50/60 Hz 660/690 V, DC-23A : 1600 A DC 250 V 4 poles in series, AC-21B : 1600 A AC 50/60 Hz 500/525 V, DC-21A : 1600 A DC 125 V 2 poles in series, AC-21B : 1600 A AC 50/60 Hz 480 V NEMA, AC-22A : 1250 A AC 50/60 Hz 500/525 V, AC-23A : 1250 A AC 50/60 Hz 220/240 V, AC-22B : 1600 A AC 50/60 Hz 480 V NEMA, AC-22B : 1600 A AC 50/60 Hz 660/690 V, AC-21A : 1250 A AC 50/60 Hz 440/480 V, AC-21B : 1600 A 50/60 Hz 440/480 V, AC-21A: 1450 A AC 50/60 Hz 380/415 V, AC-23A: 1250 A AC 50/60 Hz 440/480 V, AC-21B: 1600 A AC 50/60 Hz 380/415 V, AC-22A: 1250 A AC 50/60 Hz 440/480 V, AC-21A : 1450 A AC 50/60 Hz 220/240 V, AC-22A : 1250 A AC 50/60 Hz 660/690 V, AC-21A : 1250 A AC 50/60 Hz 480 V NEMA, AC-23A : 1250 A AC 50/60 Hz 500/525 V, DC-23A: 1600 A DC 125 V 2 poles in series, AC-22B: 1600 A AC 50/60 Hz 380/415 V, DC-22A: 1600 A DC 125 V 2 poles in series, DC-21A: 1600 A DC 250 V 4 poles in Series, AC-23A: 1250 A AC 50/60 Hz 480 V NEMA - Rated short circuit switching edge. Icm: 75 kA 690 V AC 50/60 Hz with upstream protective disconnector, 75 kA 690 V AC 50/60 Hz disconnector alone - rated operating voltage Ue: 690 V AC 50/60 Hz, 250 V DC - plus contact indication: yes - visible break: no.
Property | Value |
Number of poles: | 4.0 |
Operating power: | 710.0 kW |
Number of auxiliary contacts as normally closed: | 0.0 |
Number of auxiliary contacts as normally open: | 0.0 |
Number of auxiliary contacts as changeover contacts: | 4.0 |
Rated continuous current Iu: | 1600.0 A |
Max. Rated operating voltage Ue at AC: | 690.0 V |
Design as EMERGENCY STOP device: | yes |
Protection class (IP), front: | IP40 |
Connection type main circuit: | Screw connection |
Device design: | Built-in device, fixed installation technology |
Design of the actuating element: | long rotary handle |
Suitable for floor mounting: | yes |
Integrated motor drive: | no |
Suitable for front mounting 4-hole: | yes |
Version as maintenance/repair switch: | yes |
Voltage release optional: | no |
Suitable for front mounting central: | yes |
Suitable for intermediate installation: | no |
Suitable for distribution board installation: | yes |
Version as main switch: | yes |
Version as a safety switch: | no |
Motor drive optional: | no |
Lockable: | yes |
Version as a reversing switch: | no |
Rated short-time withstand current Icw: | 50.0 kA |
Color of the actuating element: | red |
Rated operating voltage: | 0.0 to 690.0 V |
Rated continuous current at AC-21, 400 V: | 1600.0 A |
Number of switches: | 1.0 |
Rated continuous current at AC-23, 400 V: | 1250.0 A |