FI/LS switch iC60H, 3P, 16A, C characteristic, 30mA type A, 230V AC. Circuit breaker application: Distribution - Product range: Acti 9 - Product or component type: Earth leakage circuit breaker - Device short name: FI/LS iC60H - Network type: AC - Earth fault sensitivity: 30mA - Earth fault protection time delay: instantaneous - Rated breaking capacity (lcs) according to EN/IEC61009-1 and EN/IEC 61009-2-1: 10,000 A, validation.
| Property | Value |
| Tripping characteristic: | C |
| Current: | 16.0 A |
| Fault current: | 0.03 A |
| Voltage: | 400.0 V |
| Frequency: | 50 Hz |
| Number of poles: | 3.0 |
| TE: | 3.0 |
| Residual current type: | A |
| Installation depth: | 45.0 mm |
| Rated breaking capacity according to IEC 60947-2: | 15.0 kA |
| Surge current strength: | 0.25 kA |
| Protection class (IP): | IP20 |
| Energy limitation class: | 1.0 |
| Overvoltage category: | 3.0 |
| Pollution level: | 2.0 |
| Switching neutral conductor: | yes |
| Number of protected poles: | 3.0 |
| Flush-mounted installation: | no |
| Type of voltage: | AC |
| False tripping protection: | no |
| Rated insulation voltage Ui: | 500.0 V |
| Rated impulse withstand voltage Uimp: | 4.0 kV |
| Rated breaking capacity according to EN 61009: | 10.0 kA |
| Rated switching capacity Icn according to EN 61009-1: | 10.0 kA |
| Shutdown characteristics: | undelayed |
| With locking device: | no |
| Ambient temperature during operation: | -25.0 to 40.0 °C |
| Connectable conductor cross-section, single-wire: | 1.0 to 35.0 mm² |
| Connectable conductor cross-section, multi-wire: | 1.0 to 25.0 mm² |
Features
Shutdown characteristics
Without delay
Voltage
400.0 V
Flush-mounted installation
No
HAB
IC60 3P 16A 30MA C 10KA 230VAC
Manufacturer
HAN
A9D17316
GTIN
3606481157942
Connectable conductor cross-section solid
1.0 to 35.0 mm²
Connectable conductor cross-section stranded
1.0 to 25.0 mm²
Number of protected poles
3.0
Trigger characteristics
C
Rated breaking capacity according to EN 61009
10.0kA
Rated breaking capacity according to IEC 60947-2
15.0kA
Rated insulation voltage Ui
500.0V
Rated impulse withstand voltage Uimp
4.0kV
Installation depth
45.0 mm
Energy limitation class
1.0
False trigger protection
No
Residual current type
A
Frequency
50Hz
With locking device
No
Switching neutral conductor
Yes
Number of poles
3.0
IP protection)
IP20
Voltage type
AC
Surge current strength
0.25kA
TE
3.0
Ambient temperature during operation
-25.0 to 40.0 °C
Degree of contamination
2.0
Overvoltage category
3.0