Schneider Electric A9D27225 IC60 2P 25A 30MA C SI 10KA FI/LS switch

To compare
To favorites
SKU:695549
Schneider Electric A9D27225 IC60 2P 25A 30MA C SI 10KA FI/LS switch
Shutdown characteristics
Voltage
Flush-mounted installation
HAB
In stock
€348.23
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

FI/LS switch iC60H, 2P, 25A, C characteristic, 30mA type A SI (superimmunized). Circuit breaker application: Distribution - Product range: Acti 9 - Product or component type: Earth leakage circuit breaker - Device short name: FI/LS iC60H - Neutral position: both poles possible - Protected poles: both poles - Network type: AC - Earth fault sensitivity: 30mA - Earth fault protection time delay: instantaneous - Rated breaking capacity (lcs) according to EN/IEC61009-1 and EN/IEC 61009-2-1: 10,000 A, validation..

Property Value
Tripping characteristic: C
Current: 25.0 A
Fault current: 0.03 A
Voltage: 230.0 V
Frequency: 50 Hz
Number of poles: 2.0
TE: 2.0
Residual current type: A
Installation depth: 45.0 mm
Rated breaking capacity according to IEC 60947-2: 15.0 kA
Surge current strength: 3.0 kA
Protection class (IP): IP20
Energy limitation class: 3.0
Overvoltage category: 3.0
Pollution level: 2.0
Switching neutral conductor: yes
Number of protected poles: 2.0
Flush-mounted installation: no
Voltage type: AC
False tripping protection: yes
Rated insulation voltage Ui: 500.0 V
Rated impulse withstand voltage Uimp: 4.0 kV
Rated breaking capacity according to EN 61009: 10.0 kA
Rated breaking capacity Icn according to EN 61009-1: 10.0 kA
Shutdown characteristics: undelayed
With locking device: no
Ambient temperature during operation: -25.0 to 40.0 °C
Connectable conductor cross-section, single-wire: 1.0 to 35.0 mm²
Connectable conductor cross-section, stranded: 1.0 to 25.0 mm²
Features
Shutdown characteristics
Voltage
Flush-mounted installation
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated breaking capacity according to IEC 60947-2
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles
IP protection)
Voltage type
Surge current strength
TE
Ambient temperature during operation
Degree of contamination
Overvoltage category