Description
Features
Reviews
FI/LS switch iC60H, 2P, 32A, C characteristic, 30mA type A SI (superimmunized). Circuit breaker application: Distribution - Product range: Acti 9 - Product or component type: Earth leakage circuit breaker - Device short name: FI/LS iC60H - Neutral position: both poles possible - Protected poles: both poles - Network type: AC - Earth fault sensitivity: 30mA - Earth fault protection time delay: instantaneous - Rated breaking capacity (lcs) according to EN/IEC61009-1 and EN/IEC 61009-2-1: 10,000 A, validation..
| Property | Value |
| Tripping characteristic: | C |
| Current: | 32.0 A |
| Fault current: | 0.03 A |
| Voltage: | 230.0 V |
| Frequency: | 50 Hz |
| Number of poles: | 2.0 |
| TE: | 2.0 |
| Residual current type: | other |
| Installation depth: | 45.0 mm |
| Rated breaking capacity according to IEC 60947-2: | 15.0 kA |
| Surge current strength: | 3.0 kA |
| Protection class (IP): | IP20 |
| Energy limitation class: | 3.0 |
| Overvoltage category: | 3.0 |
| Pollution level: | 2.0 |
| Switching neutral conductor: | yes |
| Number of protected poles: | 2.0 |
| Flush-mounted installation: | no |
| Voltage type: | AC |
| False tripping protection: | yes |
| Rated insulation voltage Ui: | 500.0 V |
| Rated impulse withstand voltage Uimp: | 4.0 kV |
| Rated breaking capacity according to EN 61009: | 10.0 kA |
| Rated breaking capacity Icn according to EN 61009-1: | 10.0 kA |
| Shutdown characteristics: | undelayed |
| With locking device: | no |
| Ambient temperature during operation: | -25.0 to 40.0 °C |
| Connectable conductor cross-section, single-wire: | 1.0 to 35.0 mm² |
| Connectable conductor cross-section, stranded: | 1.0 to 25.0 mm² |
Features
Shutdown characteristics
Without delay
Voltage
230.0 V
Flush-mounted installation
No
HAB
IC60 2P 32A 30MA C SI 10KA
Manufacturer
HAN
A9D27232
GTIN
3606481157461
Connectable conductor cross-section solid
1.0 to 35.0 mm²
Connectable conductor cross-section stranded
1.0 to 25.0 mm²
Number of protected poles
2.0
Trigger characteristics
C
Rated breaking capacity according to EN 61009
10.0kA
Rated breaking capacity according to IEC 60947-2
15.0kA
Rated insulation voltage Ui
500.0V
Rated impulse withstand voltage Uimp
4.0kV
Installation depth
45.0 mm
Energy limitation class
3.0
False trigger protection
Yes
Residual current type
Other
Frequency
50Hz
With locking device
No
Switching neutral conductor
Yes
Number of poles
2.0
IP protection)
IP20
Voltage type
AC
Surge current strength
3.0kA
TE
2.0
Ambient temperature during operation
-25.0 to 40.0 °C
Degree of contamination
2.0
Overvoltage category
3.0
No reviews yet — your comment may be first.
All reviews 0