Schneider Electric A9F94206 IC60L 2-pole C6A circuit breaker
Flush-mounted installation
HAB
Manufacturer
HAN
In stock
€103.86
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Miniature circuit breaker with power circuit breaker Acti 9 iC60L. 6A, characteristic C, 25kA, 2-pole. Standard: 0664 Part 21, Thermomagnetic. With error message display for short-circuit, overload and residual current tripping.

Property Value
Trip characteristic: C
Rated current: 6.0 A
Rated voltage: 400.0 V
Type of voltage: AC/DC
Frequency: 50.0 to 60.0 Hz
TE: 2.0
Number of poles (total): 2.0
Energy limitation class: 3.0
Additional equipment possible: yes
Overvoltage category: 4.0
Installation depth: 44.5 mm
Protection class (IP): IP20
Rated switching capacity Icn according to EN 60898 at 230 V: 15.0 kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 50.0 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 25.0 kA
Rated switching capacity Icn according to EN 60898 at 400 V: 15.0 kA
Pollution level: 3.0
Switching neutral conductor: no
Number of protected poles: 2.0
Flush-mounted installation: no
Rated insulation voltage Ui: 500.0 V
Rated impulse withstand voltage Uimp: 6.0 kV
Ambient temperature during operation: -35.0 to 70.0 °C
Connectable conductor cross-section, stranded: 1.0 to 16.0 mm²
Connectable conductor cross-section, single-wire: 1.0 to 25.0 mm²
Explosion-proof: no
Features
Flush-mounted installation
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icn according to EN 60898 at 230 V
Rated switching capacity Icn according to EN 60898 at 400 V
Rated switching capacity Icu according to IEC 60947-2 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 400 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Installation depth
Energy limitation class
Explosion-proof
Frequency
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
TE
Ambient temperature during operation
Degree of contamination
Additional equipment possible
Overvoltage category