Description
Features
Reviews
Miniature circuit breaker with power circuit breaker Acti 9 iC60L. 6A, characteristic C, 25kA, 2-pole. Standard: 0664 Part 21, Thermomagnetic. With error message display for short-circuit, overload and residual current tripping.
| Property | Value |
| Trip characteristic: | C |
| Rated current: | 6.0 A |
| Rated voltage: | 400.0 V |
| Type of voltage: | AC/DC |
| Frequency: | 50.0 to 60.0 Hz |
| TE: | 2.0 |
| Number of poles (total): | 2.0 |
| Energy limitation class: | 3.0 |
| Additional equipment possible: | yes |
| Overvoltage category: | 4.0 |
| Installation depth: | 44.5 mm |
| Protection class (IP): | IP20 |
| Rated switching capacity Icn according to EN 60898 at 230 V: | 15.0 kA |
| Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 50.0 kA |
| Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 25.0 kA |
| Rated switching capacity Icn according to EN 60898 at 400 V: | 15.0 kA |
| Pollution level: | 3.0 |
| Switching neutral conductor: | no |
| Number of protected poles: | 2.0 |
| Flush-mounted installation: | no |
| Rated insulation voltage Ui: | 500.0 V |
| Rated impulse withstand voltage Uimp: | 6.0 kV |
| Ambient temperature during operation: | -35.0 to 70.0 °C |
| Connectable conductor cross-section, stranded: | 1.0 to 16.0 mm² |
| Connectable conductor cross-section, single-wire: | 1.0 to 25.0 mm² |
| Explosion-proof: | no |
Features
Flush-mounted installation
No
HAB
A9F94206 IC60L 2-pin C6A
Manufacturer
HAN
A9F94206
GTIN
3606480084294
Connectable conductor cross-section solid
1.0 to 25.0 mm²
Connectable conductor cross-section stranded
1.0 to 16.0 mm²
Number of protected poles
2.0
Trigger characteristics
C
Rated insulation voltage Ui
500.0V
Rated switching capacity Icn according to EN 60898 at 230 V
15.0kA
Rated switching capacity Icn according to EN 60898 at 400 V
15.0kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
50.0kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
25.0kA
Rated voltage
400.0V
Rated impulse withstand voltage Uimp
6.0kV
Rated current
6.0A
Installation depth
44.5 mm
Energy limitation class
3.0
Explosion-proof
No
Frequency
50.0 to 60.0 Hz
Switching neutral conductor
No
Number of poles (total)
2.0
IP protection)
IP20
Voltage type
AC/DC
TE
2.0
Ambient temperature during operation
-35.0 to 70.0 °C
Degree of contamination
3.0
Additional equipment possible
Yes
Overvoltage category
4.0
No reviews yet — your comment may be first.
All reviews 0