Description
Features
Reviews

Miniature circuit breaker C120H, 1P, 125A, C characteristic. Product range: C120 - Range: Acti 9 - Product name: C120 - Product or component type: Miniature circuit breaker - Device short name: C120H - Network type: AC - Trip unit technology: thermomagnetic - Interrupting capacity: 15 kA Icu according to EN/IEC 60947-2 - 144V DC, 15 kA Icu according to EN/IEC 60947-2 - 220-240V AC 50/60 Hz, 15000 A Icn according to EN/IEC 60898-1 - 230-400V AC 50/60 Hz, 20 kA Icu according to EN/IEC 60947-2 - 12V DC, 20 kA Icu according to EN/IEC 60947-2 - 125V DC, 30 kA Icu according to EN/IEC 60947-2 - 12V AC 50/60 Hz, 30 kA Icu according to EN/IEC 60947-2 - 130V AC 50/60 Hz, 4.5 kA Icu according to EN/IEC 60947-2 - 380-415V AC 50/60 Hz IT.

Property Value
Tripping characteristic: C
Rated current: 125.0 A
Rated voltage: 415.0 V
Type of voltage: AC
Frequency: 50.0 to 60.0 Hz
TE: 1.5
Number of poles (total): 1.0
Energy limitation class: 3.0
Additional equipment possible: yes
Overvoltage category: 4.0
Installation depth: 44.0 mm
Protection class (IP): IP20
Rated switching capacity Icn according to EN 60898 at 230 V: 15.0 kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 15.0 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 4.5 kA
Pollution level: 3.0
Switching neutral conductor: no
Number of protected Poles: 2.0
Flush-mounted installation: no
Rated insulation voltage Ui: 500.0 V
Rated impulse withstand voltage Uimp: 6.0 kV
Ambient temperature during operation: -30.0 to 60.0 °C
Connectable conductor cross-section, stranded: 1.0 to 35.0 mm²
Connectable conductor cross-section, single-wire: 1.5 to 50.0 mm²
Explosion-proof: no
Features
Flush-mounted installation
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icn according to EN 60898 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 400 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Installation depth
Energy limitation class
Explosion-proof
Frequency
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
TE
Ambient temperature during operation
Degree of contamination
Additional equipment possible
Overvoltage category