Description
Features
Reviews
Miniature circuit breaker C120H, 1P, 125A, C characteristic. Product range: C120 - Range: Acti 9 - Product name: C120 - Product or component type: Miniature circuit breaker - Device short name: C120H - Network type: AC - Trip unit technology: thermomagnetic - Interrupting capacity: 15 kA Icu according to EN/IEC 60947-2 - 144V DC, 15 kA Icu according to EN/IEC 60947-2 - 220-240V AC 50/60 Hz, 15000 A Icn according to EN/IEC 60898-1 - 230-400V AC 50/60 Hz, 20 kA Icu according to EN/IEC 60947-2 - 12V DC, 20 kA Icu according to EN/IEC 60947-2 - 125V DC, 30 kA Icu according to EN/IEC 60947-2 - 12V AC 50/60 Hz, 30 kA Icu according to EN/IEC 60947-2 - 130V AC 50/60 Hz, 4.5 kA Icu according to EN/IEC 60947-2 - 380-415V AC 50/60 Hz IT.
Property | Value |
Tripping characteristic: | C |
Rated current: | 125.0 A |
Rated voltage: | 415.0 V |
Type of voltage: | AC |
Frequency: | 50.0 to 60.0 Hz |
TE: | 1.5 |
Number of poles (total): | 1.0 |
Energy limitation class: | 3.0 |
Additional equipment possible: | yes |
Overvoltage category: | 4.0 |
Installation depth: | 44.0 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 15.0 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 15.0 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 4.5 kA |
Pollution level: | 3.0 |
Switching neutral conductor: | no |
Number of protected Poles: | 2.0 |
Flush-mounted installation: | no |
Rated insulation voltage Ui: | 500.0 V |
Rated impulse withstand voltage Uimp: | 6.0 kV |
Ambient temperature during operation: | -30.0 to 60.0 °C |
Connectable conductor cross-section, stranded: | 1.0 to 35.0 mm² |
Connectable conductor cross-section, single-wire: | 1.5 to 50.0 mm² |
Explosion-proof: | no |
Features
Flush-mounted installation
No
HAB
A9N18448 C120H 1-pin C125A
Manufacturer
HAN
A9N18448
GTIN
3606480380198
Connectable conductor cross-section solid
1.5 to 50.0 mm²
Connectable conductor cross-section stranded
1.0 to 35.0 mm²
Number of protected poles
2.0
Trigger characteristics
C
Rated insulation voltage Ui
500.0V
Rated switching capacity Icn according to EN 60898 at 230 V
15.0kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
15.0kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
4.5kA
Rated voltage
415.0V
Rated impulse withstand voltage Uimp
6.0kV
Rated current
125.0A
Installation depth
44.0 mm
Energy limitation class
3.0
Explosion-proof
No
Frequency
50.0 to 60.0 Hz
Switching neutral conductor
No
Number of poles (total)
1.0
IP protection)
IP20
Voltage type
AC
TE
1.5
Ambient temperature during operation
-30.0 to 60.0 °C
Degree of contamination
3.0
Additional equipment possible
Yes
Overvoltage category
4.0
No reviews yet — your comment may be first.