PowerTag Control 2DI module. Status query of two potential-free contacts via the digital inputs. PowerTag Control wireless communication module for monitoring applications, 230V AC, 50/60Hz. The PowerTag Control module connects to a PowerTag Link module or Smartlink SI B via radio transmission. Part of the Acti9 PowerTag system - PowerTag Link or Smartlink SI B. Width 1 HP, weight 80 grams, ISM band 2.4 - 2.4835 GHz. LED light for status display on the front.
| Property | Value |
| Protection class (IP): | IP20 |
| Type of supply voltage: | AC |
| Permissible voltage at the input: | 230.0 V |
| Input current for signal 1: | 2.0 mA |
| Width: | 18.0 mm |
| Height: | 85.0 mm |
| Depth: | 62.0 mm |
| Rail mounting possible: | yes |
| Wireless standard Bluetooth: | no |
| Wireless standard WLAN 802.11: | no |
| Number of HW interfaces wireless: | 1.0 |
| Supports protocol for INTERBUS: | no |
| Design of the electrical connection: | screw connection |
| Performance level according to EN ISO 13849-1: | without |
| Supports protocol for PROFIBUS: | no |
| Supports protocol for ASI: | no |
| Rack mounting possible: | no |
| Supports protocol for PROFINET IO: | no |
| Supports protocol for PROFIsafe: | no |
| Supports protocol for PROFINET CBA: | no |
| Supports protocol for Data-Highway: | no |
| Supports protocol for SafetyBUS p: | no |
| IO-Link Master: | no |
| Supports protocol for Modbus: | no |
| Wall/direct mounting possible: | yes |
| Supports protocol for EtherNet/IP: | no |
| Supports protocol for other bus systems: | no |
| Supports protocol for SERCOS: | no |
| Supports protocol for KNX: | no |
| Supports protocol for DeviceNet Safety: | no |
| Supports protocol for SUCONET: | no |
| Front installation possible: | no |
| Number of PROFINET interfaces: | 0.0 |
| Suitable for safety functions: | no |
| Supply voltage AC 60 Hz: | 230.0 V |
| Supports protocol for TCP/IP: | no |
| Supply voltage AC 50 Hz: | 230.0 V |
| Supports protocol for CAN: | no |
| Supports protocol for Foundation Fieldbus: | no |
| Supports protocol for DeviceNet: | no |
| Supports protocol for AS-Interface Safety at Work: | no |
| Type of input voltage: | AC |
| Delay. Time: | 100.0 ms |
| Field bus connection via separate bus coupler possible: | no |
| Supports protocol for LON: | no |
| Supports protocol for INTERBUS-Safety: | no |
| System component: | no |
| Number of HW interfaces Industrial Ethernet: | 0.0 |
| Number of HW interfaces serial RS-232: | 0.0 |
| Number of HW interfaces serial RS-422: | 0.0 |
| Number of HW interfaces serial RS-485: | 0.0 |
| Number of HW interfaces serial TTY: | 0.0 |
| Number of HW interfaces parallel: | 0.0 |
| Number of HW interfaces other: | 0.0 |
| With optical interface: | no |
| Associated equipment (Ex ia): | no |
| Number of HW interfaces USB: | 0.0 |
| Associated equipment (Ex ib): | no |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | without |
| Wireless standard GSM: | no |
| Digital inputs: | 2.0 |
| Wireless standard GPRS: | no |
| Digital outputs: | 0.0 |
| SIL according to IEC 61508: | without |
| Digital outputs configurable: | no |
| Radio standard UMTS: | no |
Features
Type of voltage of the supply voltage
AC
Supports protocol for KNX
No
With optical interface
No
HAB
PowerTag C 2DI 230V, 2 digital inputs
Manufacturer
HAN
A9XMC2D3
GTIN
3606489749125
Design of the electrical connection
Screw connection
Width
18.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Height
85.0 mm
Performance Level according to EN ISO 13849-1
Without
SIL according to IEC 61508
Without
IP protection)
IP20
Depth
62.0 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
No