Description
Features
Reviews
Acti 9 Smartlink. Acti 9 Smartlink Modbus, incl. 1 x Modbus connector plug, 1 x 24VDC connector plug, 2 x mounting accessories for Multiclip 80 A. Data transfer between the Smartlink and Acti 9 devices such as circuit breakers, residual current circuit breakers, residual current devices.
| Property | Value |
| Number of PROFINET interfaces: | 0.0 |
| Number of HW interfaces Wireless: | 0.0 |
| Type of output voltage: | DC |
| Type of input voltage: | DC |
| Type of Digital output: | other |
| Design of the electrical connection: | plug connection |
| Front installation possible: | no |
| Wireless standard Bluetooth: | no |
| Wireless standard WLAN 802.11: | no |
| Suitable for safety functions: | no |
| IO-Link Master: | no |
| Performance level according to EN ISO 13849-1: | without |
| Rack mounting possible: | no |
| Type of supply voltage: | DC |
| Supports protocol for ASI: | no |
| Supports protocol for AS-Interface Safety at Work: | no |
| Supports protocol for CAN: | no |
| Supports protocol for Data-Highway: | no |
| Supports protocol for DeviceNet: | no |
| Supports protocol for DeviceNet Safety: | no |
| Supports protocol for EtherNet/IP: | no |
| Supports protocol for Foundation Fieldbus: | no |
| Supports protocol for INTERBUS: | no |
| Supports protocol for KNX: | no |
| Supports protocol for Modbus: | yes |
| Supports protocol for PROFIBUS: | no |
| Supports protocol for PROFINET CBA: | no |
| Supports protocol for PROFINET IO: | no |
| Supports protocol for PROFIsafe: | no |
| Supports protocol for SafetyBUS p: | no |
| Supports protocol for SERCOS: | no |
| Supports protocol for other bus systems: | no |
| Supports protocol for SUCONET: | no |
| Supports protocol for TCP/IP: | no |
| Supply voltage DC: | 24.0 V |
| Wall/direct mounting possible: | yes |
| Permissible voltage at the input: | 19.2 to 28.8 V |
| Input current for signal 1: | 2.5 mA |
| Output voltage at the digital output: | 24.0 V |
| Output current at the digital output: | 0.1 A |
| Short circuit protection, digital outputs available: | yes |
| Analog input, current: | no |
| Analog input, voltage: | no |
| Analog input, resistance: | no |
| Analog input, resistance thermometer: | no |
| Analog input, thermocouple: | no |
| Analog input signal configurable: | no |
| Protection class (IP): | IP20 |
| Mounting rail mounting possible: | no |
| Field bus connection possible via separate bus coupler: | no |
| Supports protocol for LON: | no |
| Supports protocol for INTERBUS-Safety: | no |
| System component: | yes |
| Number of HW interfaces Industrial Ethernet: | 0.0 |
| Number of HW interfaces serial RS-232: | 0.0 |
| Number of HW interfaces serial RS-422: | 0.0 |
| Number of HW interfaces serial RS-485: | 1.0 |
| Number of HW interfaces serial TTY: | 0.0 |
| Number of HW interfaces parallel: | 0.0 |
| Number of HW interfaces other: | 0.0 |
| With optical interface: | no |
| Associated equipment (Ex ia): | no |
| Associated equipment (Ex ib): | no |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | without |
| Width: | 359.0 mm |
| Height: | 23.0 mm |
| Depth: | 42.0 mm |
| Analog inputs configurable: | yes |
| Radio standard GPRS: | no |
| Analog outputs configurable: | no |
| Number of digital inputs: | 22.0 |
| Number of analog outputs: | 0.0 |
| Digital inputs configurable: | yes |
| Wireless standard GSM: | no |
| Number of analog inputs: | 0.0 |
| Number of digital outputs: | 11.0 |
| SIL according to IEC 61508: | without |
| Digital outputs configurable: | yes |
| Wireless standard UMTS: | no |
| Number of USB hardware interfaces: | 0.0 |
Features
Type of voltage of the supply voltage
DC
Supports protocol for KNX
No
With optical interface
No
HAB
A9XMSB11 ACTI9 11 channel MODBUS RS485
Manufacturer
HAN
A9XMSB11
GTIN
3606480430602
Design of the electrical connection
Plug connection
Width
359.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Height
23.0 mm
Performance Level according to EN ISO 13849-1
Without
SIL according to IEC 61508
Without
IP protection)
IP20
Depth
42.0 mm
Mounting rail possible
No
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
Yes
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
No
No reviews yet — your comment may be first.
All reviews 0








