Focus on centralized technical management - Immediate overview of energy consumption. Fault detection and timely intervention options: drive belt breakage, pump running dry, phase failure, power failure, etc. Preventive maintenance to minimize costs and optimize the system: fault notifications, operating times, etc. Connection to building management systems via embedded protocols. Focus on user-friendliness - Tools for installation, configuration and monitoring of the system (decentralized graphic terminal in 6 languages, multi-loader, Bluetooth and SoMove Mobile). Compact design. Easy maintenance. Focus on protection functions - Guaranteed continuous operational reliability. Permanently integrated building functions (fire protection mode, register monitoring, mechanical protection function, etc.). Integrated EMC filters, harmonic protection technology (THDI ~ 30%).
Property | Value |
Protection class (IP): | IP21 |
Number of PROFINET interfaces: | 0.0 |
Mains frequency: | 50/60 Hz |
Nominal output current: | 74.8 A |
Max. output voltage: | 240.0 V |
Mains voltage: | 200.0 to 240.0 V |
Number of input phases: | 3 |
Number of HW interfaces parallel: | 0.0 |
Number of HW interfaces other: | 0.0 |
Supports protocol for data highway: | no |
Number of HW interfaces serial RS-422: | 0.0 |
Number of HW interfaces serial RS-485: | 1.0 |
4-quadrant operation possible: | no |
Max. Output frequency: | 200.0 Hz |
Use in industrial areas permitted: | yes |
With optical interface: | no |
Height: | 330.0 mm |
Supports protocol for LON: | yes |
Width: | 245.0 mm |
Relative symmetrical mains voltage tolerance: | 10.0 % |
Supports protocol for AS-Interface Safety at Work: | no |
Depth: | 190.0 mm |
Type of converter: | U-converter |
Integrated brake chopper: | no |
Max. delivered power with linear load at rated output voltage: | 18.5 kW |
Supports protocol for TCP/IP: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFIBUS: | no |
Supports protocol for EtherNet/IP: | no |
Supports protocol for INTERBUS-Safety: | no |
Supports protocol for SUCONET: | no |
Supports protocol for CAN: | no |
Supports protocol for KNX: | no |
Use in residential and commercial areas permitted: | yes |
Supports protocol for INTERBUS: | no |
Number of HW interfaces serial RS-232: | 0.0 |
Number of HW interfaces serial TTY: | 0.0 |
Supports protocol for other bus systems: | yes |
Supports protocol for ASI: | no |
Supports protocol for SafetyBUS p: | no |
Supports protocol for Modbus: | yes |
With control element: | yes |
Supports protocol for PROFIsafe: | no |
Supports protocol for DeviceNet Safety: | no |
Number of HW interfaces Industrial Ethernet: | 0.0 |
Relative symmetrical mains frequency tolerance: | 5.0 % |
Supports protocol for SERCOS: | no |
Number of output phases: | 3 |
Supports protocol for PROFINET CBA: | no |
Supports protocol for Foundation Fieldbus: | no |
Max. delivered power at square. Load at rated output voltage: | 18.5 kW |
Number of USB hardware interfaces: | 0.0 |
With PC connection: | yes |
Number of analog outputs: | 1.0 |
Number of analog inputs: | 2.0 |
Number of digital outputs: | 0.0 |
Number of digital inputs: | 3.0 |