Frequency converter ATV630. 18.5KW, 380-480V, IP21. Precise measurement of the power consumption of the monitoring processes (deviation < 5%). Integrated Ethernet with direct access to system configuration and monitoring. Limitation of overvoltage at the motor terminals. Context-dependent access to the technical documentation through dynamic QR codes. Continuous and historical real-time measurements with customizable dashboards. Predictive and preventive maintenance tracking functions (e.g. temperatures with PT100/1000 temperature sensors, fan monitoring. Integrated safety function: STO (Safe Torque Off) SIL3. Flexible through integrated I/Os: e.g. 3 x analog inputs, including 2 for temperature sensors (PTC, PT100, PT1000, or KTY84). 6 x logic inputs 2 x analog outputs, 3 x relay outputs, 2 x safety function inputs: safety function STO. Integrated communication: Modbus/TCP, serial Modbus interface. Options: relay outputs, communication: EtherNet/IP, Modbus/TCP, CANopen Daisy Chain, ProfiNet, Profibus DP V1, DeviceNet.
Property | Value |
Degree of protection (IP): | IP21 |
Number of PROFINET interfaces: | 0.0 |
Mains frequency: | 50/60 Hz |
Nominal output current: | 39.2 A |
Max. Output voltage: | 480.0 V |
Mains voltage: | 380.0 to 480.0 V |
Number of input phases: | 3 |
Number of HW interfaces parallel: | 0.0 |
Number of HW interfaces other: | 0.0 |
Supports protocol for data highway: | no |
Number of HW interfaces serial RS-422: | 0.0 |
Number of HW interfaces serial RS-485: | 1.0 |
4-quadrant operation possible: | yes |
Max. Output frequency: | 500.0 Hz |
Use in industrial areas permitted: | yes |
With optical interface: | yes |
Height: | 546.0 mm |
Supports protocol for LON: | no |
Width: | 211.0 mm |
Relative symmetrical mains voltage tolerance: | 10.0 % |
Supports protocol for AS-Interface Safety at Work: | no |
Depth: | 232.0 mm |
Type of converter: | U-converter |
Integrated brake chopper: | no |
Max. delivered power with linear load at rated output voltage: | 18.5 kW |
Supports protocol for TCP/IP: | yes |
Supports protocol for DeviceNet: | yes |
Supports protocol for PROFINET IO: | yes |
Supports protocol for PROFIBUS: | yes |
Supports protocol for EtherNet/IP: | yes |
Supports protocol for INTERBUS-Safety: | no |
Supports protocol for SUCONET: | no |
Supports protocol for CAN: | no |
Supports protocol for KNX: | no |
Use in residential and commercial areas permitted: | yes |
Supports protocol for INTERBUS: | no |
Number of HW interfaces serial RS-232: | 0.0 |
Number of HW interfaces serial TTY: | 0.0 |
Supports protocol for other bus systems: | no |
Supports protocol for ASI: | no |
Supports protocol for SafetyBUS p: | no |
Supports protocol for Modbus: | yes |
With control element: | yes |
Supports protocol for PROFIsafe: | no |
Supports protocol for DeviceNet Safety: | no |
Number of HW interfaces Industrial Ethernet: | 1.0 |
Relative symmetrical mains frequency tolerance: | 5.0 % |
Supports protocol for SERCOS: | no |
Number of output phases: | 3 |
Supports protocol for PROFINET CBA: | no |
Supports protocol for Foundation Fieldbus: | no |
Max. delivered power at square. Load at rated output voltage: | 18.5 kW |
Number of HW interfaces USB: | 0.0 |
With PC connection: | no |
Number of analog outputs: | 2.0 |
Number of analog inputs: | 3.0 |
Number of digital outputs: | 0.0 |
Number of digital inputs: | 6.0 |
Supports protocol for BACnet: | no |