Frequency converter ATV930, wall-mounted. 5.5KW, 380-480V, IP21, with brake module. Precise measurement of the power consumption of the monitoring processes (deviation < 5%). Integrated web server with direct access to system configuration and monitoring. Simple master/slave coupling via Ethernet, with load balancing. Application functions for e.g. conveyor belts or cranes. Continuous and historical real-time measurements with customer-specific customizable dashboards. Predictive and preventive maintenance tracking functions (e.g. temperatures with PT100/1000 temperature sensors, fan monitoring). Integrated safety function: STO (Safe Torque Off) SIL3. Integrated communication: Modbus/TCP, Ethernet/IP. Serial communication: Modbus RS485 interface Options: I/O expansion cards, relay outputs, communication: EtherNet/IP, Modbus/TCP, CANopen, ProfiNet, Profibus DP V1, EtherCAT DeviceNet. Configuration and control elements: Decentralized graphical operator terminal, integrated web server, DTM (Device Type Manager), SoMove software.
| Property | Value |
| Protection class (IP): | IP21 |
| Number of PROFINET interfaces: | 0.0 |
| Mains frequency: | 50/60 Hz |
| Nominal output current: | 12.7 A |
| Max. output voltage: | 480.0 V |
| Mains voltage: | 380.0 to 480.0 V |
| Number of input phases: | 3 |
| Number of HW interfaces in parallel: | 0.0 |
| Number of other HW interfaces: | 0.0 |
| Supports protocol for data highway: | no |
| Number of HW interfaces serial RS-422: | 0.0 |
| Number of HW interfaces serial RS-485: | 3.0 |
| 4-quadrant operation possible: | yes |
| Max. Output frequency: | 500.0 Hz |
| Use in industrial areas permitted: | yes |
| With optical interface: | yes |
| Height: | 350.0 mm |
| Supports protocol for LON: | no |
| Width: | 144.0 mm |
| Relative symmetrical mains voltage tolerance: | 10.0 % |
| Supports protocol for AS-Interface Safety at Work: | no |
| Depth: | 206.0 mm |
| Type of converter: | U-converter |
| Integrated brake chopper: | no |
| Max. delivered power with linear load at rated output voltage: | 5.5 kW |
| Supports protocol for TCP/IP: | no |
| Supports protocol for DeviceNet: | yes |
| Supports protocol for PROFINET IO: | yes |
| Supports protocol for PROFIBUS: | yes |
| Supports protocol for EtherNet/IP: | yes |
| Supports protocol for INTERBUS-Safety: | no |
| Supports protocol for SUCONET: | no |
| Supports protocol for CAN: | yes |
| Supports protocol for KNX: | no |
| Permitted for use in residential and commercial areas: | yes |
| Supports protocol for INTERBUS: | no |
| Number of HW interfaces serial RS-232: | 0.0 |
| Number of HW interfaces serial TTY: | 0.0 |
| Supports protocol for other bus systems: | yes |
| Supports protocol for ASI: | no |
| Supports protocol for SafetyBUS p: | no |
| Supports protocol for Modbus: | no |
| With control element: | yes |
| Supports protocol for PROFIsafe: | no |
| Supports protocol for DeviceNet Safety: | no |
| Number of HW interfaces Industrial Ethernet: | 0.0 |
| Relative symmetrical mains frequency tolerance: | 5.0 % |
| Supports protocol for SERCOS: | no |
| Number of output phases: | 3 |
| Supports protocol for PROFINET CBA: | no |
| Supports protocol for Foundation Fieldbus: | no |
| Max. delivered power at square. Load at rated output voltage: | 5.5 kW |
| Number of USB hardware interfaces: | 0.0 |
| With PC connection: | no |
| Number of analog outputs: | 2.0 |
| Number of analog inputs: | 3.0 |
| Number of digital outputs: | 1.0 |
| Number of digital inputs: | 8.0 |
| Supports protocol for BACnet: | no |