Circuit breaker Easypact EZC100H, TMD, 60A- 3p3D. Product series: EasyPact - Product or component type: Circuit breaker - Device short name: Easypact EZC100H - Circuit breaker designation: Easypact EZC100H - Device application: Distribution - Description of protected poles: 3t - Network connection: DC, AC - Network frequency: 50/60 Hz - Rated operating voltage Ue: 250 V DC according to IEC 60947-2, 550 V AC 50/60 Hz according to IEC 60947-2 - Line breaker performance index: H - Breaking capacity: 100 kA Icu at 110...130 V AC 50/60 Hz according to IEC 60947-2, 100 kA at 240 V AC 50/60 Hz according to NEMA AB1, 10 kA Icu at 125 V DC 1P according to IEC 60947-2, 18 kA at 277/480 V AC 50/60 Hz according to NEMA AB1, 10 kA Icu at 250 V DC 2P according to IEC 60947-2, 30 kA Icu at 380 V AC 50/60 Hz according to IEC 60947-2, 10 kA Icu at 550 V AC 50/60 Hz according to IEC 60947-2, 100 kA Icu at 220...240 V AC 50/60 Hz according to IEC 60947-2, 30 kA Icu at 400...415 V AC 50/60 Hz according to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz according to IEC 60947-2 - Rated operating breaking capacity. Ics: Ics 10 kA 440 V AC 50/60 Hz according to IEC 60947-2, Ics 5 kA 250 V DC according to IEC 60947-2, Ics 15 kA 400/415 V AC 50/60 Hz according to IEC 60947-2, Ics 5 kA 125 V DC according to IEC 60947-2, Ics 50 kA 220/230/240 V AC 50/60 Hz according to IEC 60947-2, Ics 15 kA 380 V AC 50/60 Hz according to IEC 60947-2, Ics 50 kA 110/130 V AC 50/60 Hz according to IEC 60947-2, Ics 5 kA 550 V AC 50/60 Hz according to IEC 60947-2 - Usage category: Category A - Designation of trip unit: TM-D - Technology of trip unit: thermomagnetic - Protection functions: overload protection, short-circuit protection - Pollution degree: 3 according to IEC 947-1, 3 according to IEC 60664-1.
| Property | Value |
| Rated continuous current Iu: | 100.0 A |
| Type of connection main circuit: | Screw connection |
| Number of poles: | 3.0 |
| Auxiliary contact: | 0.0 |
| Opener auxiliary circuit: | 0.0 |
| Device design: | Built-in device, fixed installation technology |
| Position of the connection for main circuit: | front |
| Protection class (IP): | IP20 |
| Overload release current setting: | 0.0 to 60.0 A |
| Rated voltage: | 550.0 V |
| Icu at 400V: | 30.0 kA |
| Suitable for DIN rail mounting: | no |
| Design of the actuating element: | toggle |
| With integrated undervoltage release: | no |
| Integrated earth fault protection: | no |
| Integrated motor drive: | no |
| Optional motor drive: | no |
| With tripped indicator: | yes |
| Number of auxiliary contacts as changeover contacts: | 0.0 |
| Complete device with protection unit: | yes |
| DIN rail mounting optional: | no |