Circuit breaker Easypact EZC100N, TMD, 63A, 4p/3d. Product range: EasyPact - Product or component type: Circuit breaker - Device short name: Easypact EZC100N - Circuit breaker designation: Easypact EZC100N - Device application: Distribution - Description of protected poles: 3t - Network connection: DC, AC - Network frequency: 50/60 Hz - Rated operating voltage Ue: 250 V DC according to IEC 60947-2, 550 V AC 50/60 Hz according to IEC 60947-2 - Line break performance index: N - Breaking capacity: 25 kA Icu at 220...240 V AC 50/60 Hz according to IEC 60947-2, 5 kA Icu at 550 V AC 50/60 Hz according to IEC 60947-2, 10 kA HIC at 277/480 V AC 50/60 Hz according to NEMA AB1, 5 kA Icu at 250 V DC 2P according to IEC 60947-2, 10 kA Icu at 440 V AC 50/60 Hz according to IEC 60947-2, 25 kA HIC at 240 V AC 50/60 Hz according to NEMA AB1, 18 kA Icu at 380...400 V AC 50/60 Hz according to IEC 60947-2, 5 kA Icu at 125 V DC 1P according to IEC 60947-2, 15 kA Icu at 415 V AC 50/60 Hz according to IEC 60947-2, 25 kA Icu at 110...130 V AC 50/60 Hz according to IEC 60947-2 - Rated operating breaking capacity. Ics: Ics 12.5 kA 110...130 V AC 50/60 Hz according to IEC 60947-2, Ics 2.5 kA 550 V AC 50/60 Hz according to IEC 60947-2, Ics 9 kA 380...400 V AC 50/60 Hz according to IEC 60947-2, Ics 7.5 kA 415 V AC 50/60 Hz according to IEC 60947-2, Ics 5 kA 440 V AC 50/60 Hz according to IEC 60947-2, Ics 12.5 kA 220...240 V AC 50/60 Hz according to IEC 60947-2, Ics 2.5 kA 125 V DC according to IEC 60947-2, Ics 2.5 kA 250 V DC according to IEC 60947-2 - Utilization category: Category A - Designation of trip unit: TM-D - Technology of trip unit: thermomagnetic - Protection functions: overload protection, short-circuit protection.
| Property | Value |
| Rated continuous current Iu: | 63.0 A |
| Type of connection main circuit: | Screw connection |
| Number of poles: | 4.0 |
| Auxiliary contact normally open: | 2.0 |
| Auxiliary contact normally closed: | 2.0 |
| Device design: | Built-in device, fixed installation technology |
| Position of the connection for the main circuit: | front |
| Protection class (IP): | IP20 |
| Rated voltage: | 550.0 V |
| Icu at 400V: | 18.0 kA |
| Suitable for DIN rail mounting: | yes |
| Design of the actuating element: | toggle |
| With integrated Undervoltage release: | no |
| Integrated earth fault protection: | no |
| Motor drive integrated: | no |
| Motor drive optional: | no |
| With trip detector: | yes |
| Number of auxiliary contacts as changeover contacts: | 2.0 |
| Complete device with protection unit: | yes |
| DIN rail mounting optional: | yes |