+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Send message to
WhatsApp
Send message to
Telegram
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Switches & Sockets
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Schneider Electric GV2ME06K1BW3 0.55KW 24VDC 1-turn direct starter

To compare
To favorites
SKU:679367
Schneider Electric GV2ME06K1BW3 0.55KW 24VDC 1-turn direct starter
With fuse
Rated operating current Ie
External reset possible
With transformer
In stock
€106.51
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Motor protection switches with thermal and magnetic release These devices are easy to use and set up, with compact and ergonomic products for requirements in the field of starter motors and stop motors.

Feature Value
Overload release current setting: 1.0 to 1.6 A
Voltage type for actuation: DC
Connection type main circuit: Screw connection
Operating power: 0.55 kW
Rated operating current Ie: 1.6 A
Rated voltage DC: 24.0 V
With short-circuit release: yes
Protection class (IP): IP20
Supports protocol for SafetyBUS p: no
Number of auxiliary contacts as normally closed: 0.0
Supports protocol for INTERBUS: no
Supports protocol for CAN: no
Supports protocol for ASI: no
Design of electrical connection for auxiliary and control circuit: screw connection
Supports protocol for Foundation Fieldbus: no
Supports protocol for Data Highway: no
Supports protocol for Modbus: no
Trigger class: CLASS 10
Supports protocol for PROFINET IO: no
Supports protocol for TCP/IP: no
Supports protocol for SERCOS: no
Temperature compensated overload protection: yes
Supports protocol for EtherNet/IP: no
Supports protocol for other bus systems: no
Supports protocol for PROFINET CBA: no
Type of motor starter: Direct-on-line starter (DOL)
Rated operating current at AC-3, 400 V: 1.6 A
Supports protocol for SUCONET: no
DIN rail mounting possible: yes
Supports protocol for PROFIsafe: no
Supports protocol for DeviceNet: no
Supports protocol for LON: no
Supports protocol for DeviceNet Safety: no
Ambient temperature, upper limit without restrictions: 50.0 °C
Conditional rated short-circuit current, allocation type 1, 480 Y/277 V: 50000.0 A
Rated operating power at AC-3, 230 V, 3-phase: 0.25 kW
Supports protocol for PROFIBUS: no
Number of auxiliary contacts as normally open: 1.0
Supports protocol for AS-Interface Safety at Work: no
Supports protocol for INTERBUS-Safety: no
Conditional rated short-circuit current, allocation type 1, 600 Y/347 V: 50000.0 A
Rated power, 460 V, 60 Hz, 3-phase: 0.55 kW
Rated power, 575 V, 60 Hz, 3-phase: 0.75 kW
With transformer: no
Number of command points: 2.0
Suitable for EMERGENCY STOP: no
Assignment type according to IEC 60947-4-3: Class 1
Number of indicator lights: 0.0
External reset possible: no
With fuse: no
Width: 45.0 mm
Height: 152.0 mm
Depth: 77.0 mm
Features
With fuse
Rated operating current Ie
External reset possible
With transformer
Design of electrical connection for auxiliary and control circuit
Type of motor starter
Rated operating current at AC-3, 400 V
With short-circuit release
Temperature-compensated overload protection
Ambient temperature, upper limit without restrictions
Rated operating power at AC-3, 230 V, 3-phase
Assignment type according to IEC 60947-4-3
HAB
Manufacturer
HAN
GTIN
Connection type main circuit
Number of command posts
Number of auxiliary contacts as normally open
Number of auxiliary contacts as normally closed
Trigger class
Width
Suitable for EMERGENCY STOP
Height
IP protection)
Voltage type for actuation
Depth
Mounting rail possible
Supports protocol for AS-Interface Safety at Work
Supports protocol for ASI
Supports protocol for CAN
Supports data highway protocol
Supports protocol for DeviceNet
Supports protocol for DeviceNet Safety
Supports protocol for EtherNet/IP
Supports protocol for Foundation Fieldbus
Supports protocol for INTERBUS
Supports protocol for INTERBUS-Safety
Supports protocol for LON
Supports protocol for Modbus
Supports protocol for PROFIBUS
Supports protocol for PROFINET CBA
Supports protocol for PROFINET IO
Supports protocol for PROFIsafe
Supports protocol for SERCOS
Supports protocol for SUCONET
Supports protocol for SafetyBUS p
Supports protocol for TCP/IP
Supports protocol for other bus systems
Overload release current setting
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Schneider Electric LE1M35M705 IP65 direct starter
Schneider Electric LE1M35M705 IP65 direct starter
106.51
In stock
Schneider Electric LE1M35M706 IP65 direct starter
Schneider Electric LE1M35M706 IP65 direct starter
106.51
In stock
Schneider Electric LE1M35M707 IP65 direct starter
Schneider Electric LE1M35M707 IP65 direct starter
106.51
In stock
Schneider Electric LE1M35M708 IP65 direct starter
Schneider Electric LE1M35M708 IP65 direct starter
106.51
In stock
Schneider Electric LE1M35M710 IP65 direct starter
Schneider Electric LE1M35M710 IP65 direct starter
106.51
In stock
Schneider Electric LE1M35M712 IP65 direct starter
Schneider Electric LE1M35M712 IP65 direct starter
106.51
In stock
Schneider Electric LE1M35P708 IP65 direct starter
Schneider Electric LE1M35P708 IP65 direct starter
106.51
In stock
Schneider Electric NSYSBM208012 flat 200x800x120mm enclosure
Schneider Electric NSYSBM208012 flat 200x800x120mm enclosure
106.51
In stock