Description
Features
Reviews
Direct starter with magnetic release up to 15 kWThe combination of TeSys GV2 motor protection switch with TeSys D contactor guarantees maximum reliability, compact designs and the easiest selection.
| Property | Value |
| Voltage type for actuation: | AC |
| Connection type main circuit: | Screw connection |
| Operating power: | 7.5 kW |
| Rated operating current Ie: | 18.0 A |
| Rated voltage AC: | 380.0 V |
| Rated control supply voltage AC 60 Hz: | 380.0 V |
| With short-circuit release: | yes |
| Protection class (IP): | IP65 |
| Supports protocol for SafetyBUS p: | no |
| Number of auxiliary contacts as normally closed: | 0.0 |
| Supports protocol for INTERBUS: | no |
| Supports protocol for CAN: | no |
| Supports protocol for ASI: | no |
| Design of electrical connection for auxiliary and control circuit: | screw connection |
| Supports protocol for Foundation Fieldbus: | no |
| Supports protocol for Data Highway: | no |
| Supports protocol for Modbus: | no |
| Supports protocol for PROFINET IO: | no |
| Supports protocol for TCP/IP: | no |
| Supports protocol for SERCOS: | no |
| Temperature compensated overload protection: | no |
| Supports protocol for EtherNet/IP: | no |
| Supports protocol for other bus systems: | no |
| Supports protocol for PROFINET CBA: | no |
| Type of motor starter: | Direct starter (DOL) |
| Rated operating current at AC-3, 400 V: | 18.0 A |
| Supports protocol for SUCONET: | no |
| DIN rail mounting possible: | no |
| Supports protocol for PROFIsafe: | no |
| Supports protocol for DeviceNet: | no |
| Supports protocol for LON: | no |
| Supports protocol for DeviceNet Safety: | no |
| Ambient temperature, upper limit without restrictions: | 40.0 °C |
| Rated operating power at AC-3, 230 V, 3-phase: | 4.0 kW |
| Supports protocol for PROFIBUS: | no |
| Number of auxiliary contacts as normally open: | 0.0 |
| Supports protocol for AS-Interface Safety at Work: | no |
| Supports protocol for INTERBUS-Safety: | no |
| Rated power, 460 V, 60 Hz, 3-phase: | 7.5 kW |
| Rated power, 575 V, 60 Hz, 3-phase: | 11.0 kW |
| With transformer: | no |
| Number of command points: | 2.0 |
| Suitable for EMERGENCY STOP: | no |
| Assignment type according to IEC 60947-4-3: | Class 1 |
| Number of indicator lights: | 0.0 |
| External reset possible: | yes |
| With fuse: | yes |
| Width: | 186.0 mm |
| Height: | 348.0 mm |
| Depth: | 176.0 mm |
Features
With fuse
Yes
Rated operating current Ie
18.0 A
External reset possible
Yes
With transformer
No
Design of electrical connection for auxiliary and control circuit
Screw connection
Type of motor starter
Direct starter (DOL)
Rated operating current at AC-3, 400 V
18.0 A
With short-circuit release
Yes
Temperature-compensated overload protection
No
Ambient temperature, upper limit without restrictions
40.0 °C
Rated operating power at AC-3, 230 V, 3-phase
4.0 kW
Assignment type according to IEC 60947-4-3
Class 1
HAB
LE4D18Q7 3-pole 18A 380V 50760 HZ
Manufacturer
HAN
LE4D18Q7
GTIN
3389110074604
Connection type main circuit
Screw connection
Number of command posts
2.0
Number of auxiliary contacts as normally open
0.0
Number of auxiliary contacts as normally closed
0.0
Width
186.0 mm
Suitable for EMERGENCY STOP
No
Height
348.0 mm
IP protection)
IP65
Voltage type for actuation
AC
Depth
176.0 mm
Mounting rail possible
No
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
No
No reviews yet — your comment may be first.
All reviews 0