Motor feeders TeSys U is the first intelligent motor feeder that combines control, switching and protection in one device. Compact, simple and modular, it adapts to all applications.
| Property | Value |
| Voltage type for actuation: | AC |
| Connection type main circuit: | Screw connection |
| Operating power: | 5.5 kW |
| Rated operating current Ie: | 12.0 A |
| Rated voltage AC: | 24.0 V |
| Rated control supply voltage AC 60 Hz: | 24.0 V |
| With short-circuit release: | yes |
| Protection class (IP): | IP20 |
| Supports protocol for SafetyBUS p: | no |
| Number of auxiliary contacts as normally closed contacts: | 1.0 |
| Supports protocol for INTERBUS: | no |
| Supports protocol for CAN: | no |
| Supports protocol for ASI: | no |
| Design of electrical connection for auxiliary and control circuit: | Screw connection |
| Supports protocol for Foundation Fieldbus: | no |
| Conditional rated short-circuit current, allocation type 2, 230 V: | 50000.0 A |
| Supports protocol for Data Highway: | no |
| Supports protocol for Modbus: | no |
| Supports protocol for PROFINET IO: | no |
| Supports protocol for TCP/IP: | no |
| Supports protocol for SERCOS: | no |
| Supports protocol for EtherNet/IP: | no |
| Supports protocol for other bus systems: | no |
| Supports protocol for PROFINET CBA: | no |
| Type of motor starter: | Reversing starter |
| Rated operating current at AC-3, 400 V: | 12.0 A |
| Supports protocol for SUCONET: | no |
| Mounting rail mounting possible: | yes |
| Supports protocol for PROFIsafe: | no |
| Supports protocol for DeviceNet: | no |
| Supports protocol for LON: | no |
| Supports protocol for DeviceNet Safety: | no |
| Ambient temperature, upper limit without restrictions: | 70.0 °C |
| Conditional rated short-circuit current, allocation type 1, 480 Y/277 V: | 10000.0 A |
| Rated operating power at AC-3, 230 V, 3-phase: | 3.0 kW |
| Conditional rated short-circuit current, allocation type 2, 400 V: | 50000.0 A |
| Supports protocol for PROFIBUS: | no |
| Number of auxiliary contacts as normally open: | 1.0 |
| Supports protocol for AS-Interface Safety at Work: | no |
| Supports protocol for INTERBUS-Safety: | no |
| Conditional rated short-circuit current, allocation type 1, 600 Y/347 V: | 4000.0 A |
| Rated power, 460 V, 60 Hz, 3-phase: | 5.5 kW |
| Rated power, 575 V, 60 Hz, 3-phase: | 5.5 kW |
| With transformer: | no |
| Number of command points: | 3.0 |
| Suitable for EMERGENCY STOP: | no |
| Assignment type according to IEC 60947-4-3: | Class 2 |
| Number of indicator lights: | 0.0 |
| External reset possible: | no |
| With fuse: | no |
| Width: | 45.0 mm |
| Height: | 224.0 mm |
| Depth: | 126.0 mm |
Features
With fuse
No
Rated operating current Ie
12.0 A
External reset possible
No
With transformer
No
Design of electrical connection for auxiliary and control circuit
Screw connection
Type of motor starter
Reversing starter
Rated operating current at AC-3, 400 V
12.0 A
With short-circuit release
Yes
Ambient temperature, upper limit without restrictions
70.0 °C
Rated operating power at AC-3, 230 V, 3-phase
3.0 kW
Assignment type according to IEC 60947-4-3
Class 2
Conditional rated short circuit current, allocation type 2, 400 V
50000.0 A
HAB
LU2B12B 12A 24V AC
Manufacturer
HAN
LU2B12B
GTIN
3389110362947
Connection type main circuit
Screw connection
Number of command posts
3.0
Number of auxiliary contacts as normally open
1.0
Number of auxiliary contacts as normally closed
1.0
Width
45.0 mm
Suitable for EMERGENCY STOP
No
Height
224.0 mm
IP protection)
IP20
Voltage type for actuation
AC
Depth
126.0 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
No