Schneider Electric M9F23313 M9 C60SP 3P 13A D UL1077 miniature circuit breaker

To compare
To favorites
SKU:696144
Schneider Electric M9F23313 M9 C60SP 3P 13A D UL1077 miniature circuit breaker
Flush-mounted installation
HAB
Manufacturer
HAN
In stock
€47.02
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Circuit breaker C60SP - Product or component type: MCB - Miniature circuit breaker - Device abbreviation: C60SP UL1077 - Trip unit technology: thermomagnetic - Tripping characteristics B, C, D - Standards: UL 1077 / CSA C22.2 No. 235 / IEC/EN 60947-2 / GB 14048-2 - Connection: cage terminals - Voltage: AC

Property Value
Tripping characteristic: D
Rated current: 13.0 A
Rated voltage: 277.0 V
Voltage type: AC
Frequency: 50.0 to 60.0 Hz
TE: 6.0
Number of poles (total): 3.0
Additional devices possible: yes
Overvoltage category: 4.0
Installation depth: 44.0 mm
Protection class (IP): IP20
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 20.0 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 10.0 kA
Pollution level: 3.0
Switching neutral conductor: yes
Number of protected poles: 3.0
Flush-mounted installation: no
Rated insulation voltage Ui: 500.0 V
Rated impulse withstand voltage Uimp: 6.0 kV
Ambient temperature during operation: -30.0 to 70.0 °C
Connectable conductor cross-section, stranded: 1.0 to 16.0 mm²
Connectable conductor cross-section, single-wire: 1.0 to 25.0 mm²
Explosion-proof: no
Features
Flush-mounted installation
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icu according to IEC 60947-2 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 400 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Installation depth
Explosion-proof
Frequency
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
TE
Ambient temperature during operation
Degree of contamination
Additional equipment possible
Overvoltage category
No reviews yet — your comment may be first.