Residual current circuit breaker Resi9. 1 pole + N, 16A. B characteristic, nominal residual current 10 mA, type A, rated breaking capacity 10kA, in accordance with EN/IEC 61009-1. Operating voltage (Ue) 230V AC, operating frequency 50 Hz, neutral position on the left. Residual current circuit breaker with integrated circuit breaker, mechanical red indicator when the circuit breaker is tripped and separate mechanical red indicator when the residual current circuit breaker is tripped on the front of the device. Color RAL 9003
Property | Value |
Triggering characteristics: | B |
Current: | 16.0 A |
Fault current: | 0.01 A |
Voltage: | 230.0 V |
Frequency: | 50/60 Hz |
Number of poles: | 2.0 |
TE: | 2.0 |
Fault current type: | A |
Installation depth: | 44.5 mm |
Surge current strength: | 0.25 kA |
Protection class (IP): | IP20 |
Energy limitation class: | 3.0 |
Overvoltage category: | 3.0 |
Pollution degree: | 2.0 |
Switching neutral conductor: | yes |
Number of protected poles: | 1.0 |
Flush-mounted installation: | no |
Type of voltage: | AC |
False tripping protection: | no |
Rated insulation voltage Ui: | 440.0 V |
Rated impulse withstand voltage Uimp: | 4.0 kV |
Rated breaking capacity according to EN 61009: | 6.0 kA |
Rated switching capacity Icn according to EN 61009-1: | 6.0 kA |
Shut-down characteristic: | undelayed |
With locking device: | yes |
Ambient temperature during operation: | -25.0 to 40.0 °C |
Connectable conductor cross-section, single-wire: | 1.0 to 25.0 mm² |
Connectable conductor cross-section, stranded: | 1.0 to 16.0 mm² |
Features
Shutdown characteristics
Without delay
Voltage
230.0 V
Flush-mounted installation
No
HAB
Resi9 1P+N 16A B-Char. 10mA Type A 6kA
Manufacturer
HAN
R9D03616
GTIN
3606489662080
Connectable conductor cross-section solid
1.0 to 25.0 mm²
Connectable conductor cross-section stranded
1.0 to 16.0 mm²
Number of protected poles
1.0
Trigger characteristics
B
Rated breaking capacity according to EN 61009
6.0kA
Rated insulation voltage Ui
440.0V
Rated impulse withstand voltage Uimp
4.0kV
Installation depth
44.5 mm
Energy limitation class
3.0
False trigger protection
No
Residual current type
A
Frequency
50/60Hz
With locking device
Yes
Switching neutral conductor
Yes
Number of poles
2.0
IP protection)
IP20
Voltage type
AC
Surge current strength
0.25kA
TE
2.0
Ambient temperature during operation
-25.0 to 40.0 °C
Degree of contamination
2.0
Overvoltage category
3.0