Description
Features
Reviews
I/O expansion module for Modicon M172 PLC controllers. The module has a total of 28 integrated I/Os, of which 6 are digital (potential-free / HSC) and 10 configurable (U/I/T/R) analog inputs, 10 digital & 2 configurable (U/I/PWM) analog outputs. The power supply is via 24 VAC / 24 VDC. The digital outputs are designed as relays (SPST, 3A). The connections are made using removable screw terminal blocks (not included in delivery). Mounting on 35mm top hat rail. Certified according to cURus (UL recognized), CSA, EAC, RCM.
| Property | Value |
| Height: | 110.0 mm |
| Width: | 72.0 mm |
| Depth: | 59.0 mm |
| Wireless standard WLAN 802.11: | no |
| With display: | no |
| Wireless standard Bluetooth: | no |
| Suitable for Safety functions: | no |
| Number of PROFINET interfaces: | 0.0 |
| Number of wireless hardware interfaces: | 0.0 |
| Supports protocol for INTERBUS: | no |
| Front installation possible: | no |
| Rack mounting possible: | no |
| Performance level according to EN ISO 13849-1: | without |
| IO-Link Master: | no |
| Redundancy capability: | no |
| Type of supply voltage: | AC/DC |
| Supply voltage AC 50 Hz: | 24.0 V |
| Supply voltage AC 60 Hz: | 24.0 V |
| Supply voltage DC: | 20.0 to 38.0 V |
| Storage type: | other |
| Wall/direct mounting possible: | yes |
| System component: | no |
| Rail mounting possible: | yes |
| Number of relay outputs: | 5.0 |
| Processing time (1K, binary instruction): | 0.3 ms |
| Supports protocol for DeviceNet Safety: | no |
| Supports protocol for CAN: | yes |
| Supports protocol for SERCOS: | no |
| Supports protocol for KNX: | no |
| Supports protocol for SUCONET: | no |
| Supports protocol for SafetyBUS p: | no |
| Supports protocol for Modbus: | no |
| Supports protocol for PROFINET IO: | no |
| Supports protocol for EtherNet/IP: | no |
| Supports protocol for Foundation Fieldbus: | no |
| Supports protocol for DeviceNet: | no |
| Supports protocol for PROFIsafe: | no |
| Supports protocol for AS-Interface Safety at Work: | no |
| Supports protocol for Data-Highway: | no |
| Supports protocol for PROFINET CBA: | no |
| Supports protocol for other bus systems: | no |
| Supports protocol for TCP/IP: | no |
| Supports protocol for PROFIBUS: | no |
| Supports protocol for INTERBUS-Safety: | no |
| Supports protocol for ASI: | no |
| Supports protocol for LON: | no |
| Max. Number of timers: | 0.0 |
| Design: | compact |
| Memory size: | 0.512 kByte |
| Number of HW interfaces Industrial Ethernet: | 0.0 |
| Number of HW interfaces serial RS-232: | 0.0 |
| Number of HW interfaces serial RS-422: | 0.0 |
| Number of HW interfaces serial RS-485: | 0.0 |
| Number of USB hardware interfaces: | 0.0 |
| Number of parallel hardware interfaces: | 0.0 |
| Number of other hardware interfaces: | 1.0 |
| With optical interface: | no |
| Program memory expansion possible: | no |
| Associated equipment (Ex ia): | no |
| Associated equipment (Ex ib): | no |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | without |
| Wireless standard GSM: | no |
| Number of analog inputs: | 10.0 |
| Number of digital inputs: | 6.0 |
| Wireless standard GPRS: | no |
| Number of analog outputs: | 2.0 |
| SIL according to IEC 61508: | without |
| Number of digital outputs: | 10.0 |
| Wireless standard UMTS: | no |
| Supports protocol for DNP3: | no |
| Supports protocol for IEC 60870: | no |
| Supports protocol for IEC 61850 Ethernet: | no |
| LTE: | no |
Features
Type of voltage of the supply voltage
AC/DC
Supports protocol for KNX
No
With optical interface
No
HAB
Modicon M172 28 I/O 24 VAC/DC
Manufacturer
HAN
TM172E28R
GTIN
3606481267627
Version
Compact
Width
72.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Height
110.0 mm
With display
No
Performance Level according to EN ISO 13849-1
Without
SIL according to IEC 61508
Without
Depth
59.0 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
Yes
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
No