Description
Features
Reviews
Metal safety position switch with separate actuator and locking mechanism. XCSLF metal safety position switch, magnetic XCSLF, 2 NC + 4 NO, step switching, 1 threaded hole M20 - 24V. Reversible drive head, protection class IP67, 3 cable entries M20 x 1.5. Positive opening auxiliary switch, without snap action, dimensions 43.6 x 50.6 x 205 mm. Connection spring-loaded terminals, 2 LED displays. Locking by de-energized state, unlocking by switching on the electromagnet, coil voltage 24 V AC/DC.
| Property | Value |
| Number of contacts as normally closed: | 1.0 |
| Number of contacts as normally open: | 2.0 |
| Number of contacts as changeover: | 0.0 |
| Number of safety-related auxiliary contacts: | 0.0 |
| Design of the interface: | without |
| Design of the interface for safety-related Communication: | without |
| Design of the electrical connection: | Cable entry (metric) |
| Design of the switching element: | Slow-action switching element |
| Rated operating current Ie at AC-15, 230 V: | 0.75 A |
| Rated operating current Ie at DC-13, 24 V: | 0.55 A |
| Rated control supply voltage magnetic drive AC 50 Hz: | 24.0 V |
| Rated control supply voltage magnetic drive AC 60 Hz: | 24.0 V |
| Rated control supply voltage magnetic drive DC: | 24.0 V |
| Width of the sensor: | 44.0 mm |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | other |
| Suitable for safety functions: | yes |
| Housing design: | other |
| Height of the sensor: | 205.0 mm |
| Sensor length: | 51.0 mm |
| With escape release: | no |
| With status display: | yes |
| Protection class (IP): | IP67K |
| Ambient temperature during operation: | -25.0 to 60.0 °C |
| Housing material: | Metal |
| Closing force: | 20.0 N |
| Type of locking: | Closed-circuit principle |
| With auxiliary release: | no |
| Housing coating: | other |
Features
HAB
XCSLF-Si- Met.magn. XCSLF 2 Ö+4 S- gest.
Manufacturer
HAN
XCSLF3535312
GTIN
3606489413347
Number of contacts as normally open
2.0
Number of contacts as changeover
0.0
Number of contacts as opener
1.0
Number of safety-related auxiliary contacts
0.0
Implementation of the interface
Without
Design of the interface for safety-related communication
Without
Design of the electrical connection
Cable entry (metric)
Rated operating current Ie at AC-15, 230 V
0.75A
Rated operating current Ie at DC-13, 24 V
0.55A
Housing coating
Other
Width of the sensor
44.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Other
Suitable for security functions
Yes
Housing design
Other
Height of the sensor
205.0 mm
Length of the sensor
51.0 mm
With status display
Yes
IP protection)
IP67K
Ambient temperature during operation
-25.0 to 60.0 °C
Housing material
Metal
No reviews yet — your comment may be first.