Description
Features
Reviews
XCSTE safety position switch, plastic-encapsulated, 1 break contact and 1 make contact, stepped switching, 1 cable entry
| Property | Value |
| Number of contacts as break contacts: | 1.0 |
| Number of contacts as make contacts: | 1.0 |
| Number of contacts as changeover contacts: | 0.0 |
| Number of safety-related auxiliary contacts: | 0.0 |
| Interface design: | without |
| Design of the interface for safety-related communication: | without |
| Design of the electrical connection: | other |
| Design of the switching element: | slow-action switching element |
| Rated operating current Ie at AC-15, 125 V: | 3.0 A |
| Rated operating current Ie at AC-15, 230 V: | 1.5 A |
| Rated operating current Ie at DC-13, 125 V: | 0.55 A |
| Rated operating current Ie at DC-13, 230 V: | 0.27 A |
| Rated control supply voltage magnetic drive AC 50 Hz: | 24.0 V |
| Rated control supply voltage magnetic drive AC 60 Hz: | 24.0 V |
| Rated control supply voltage magnetic drive DC: | 24.0 V |
| Width of the sensor: | 110.0 mm |
| Explosion protection category for gas: | without |
| Explosion protection category for Dust: | without |
| Suitable for safety functions: | yes |
| Housing design: | Cuboid |
| Height of sensor: | 94.0 mm |
| Length of sensor: | 33.0 mm |
| With escape release: | no |
| With status display: | yes |
| Protection class (IP): | IP67K |
| Ambient temperature during operation: | -25.0 to 60.0 °C |
| Housing material: | Plastic |
| Locking force: | 500.0 N |
| Type of locking: | Closed-circuit principle |
| With auxiliary release: | no |
| Housing coating: | other |
Features
Rated operating current Ie at DC-13, 230 V
0.27 A
Rated operating current Ie at DC-13, 125 V
0.55 A
Rated operating current Ie at AC-15, 125 V
3.0 A
HAB
XCSTE5313 NPT OES Solenoid 24V ON
Manufacturer
HAN
XCSTE5313
GTIN
3389110825091
Number of contacts as normally open
1.0
Number of contacts as changeover
0.0
Number of contacts as opener
1.0
Number of safety-related auxiliary contacts
0.0
Implementation of the interface
Without
Design of the interface for safety-related communication
Without
Design of the electrical connection
Other
Rated operating current Ie at AC-15, 230 V
1.5A
Housing coating
Other
Width of the sensor
110.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
Yes
Housing design
Cuboid
Height of the sensor
94.0 mm
Length of the sensor
33.0 mm
With status display
Yes
IP protection)
IP67K
Ambient temperature during operation
-25.0 to 60.0 °C
Housing material
Plastic
No reviews yet — your comment may be first.