Description
Features
Reviews
XCSTE safety position switch, plastic-encapsulated, 2 break contacts, stepped switching, 1 cable entry.
| Property | Value |
| Number of contacts as break contacts: | 2.0 |
| Number of contacts as make contacts: | 0.0 |
| Number of contacts as changeover contacts: | 0.0 |
| Number of safety-related auxiliary contacts: | 0.0 |
| Design of the interface: | without |
| Design of the interface for safety-related communication: | without |
| Design of the electrical connection: | Cable entry PG |
| Design of the switching element: | Slow-action switching element |
| Rated operating current Ie at AC-15, 125 V: | 3.0 A |
| Rated operating current Ie at AC-15, 230 V: | 1.5 A |
| Rated operating current Ie at DC-13, 125 V: | 0.55 A |
| Rated operating current Ie at DC-13, 230 V: | 0.27 A |
| Rated control supply voltage magnetic drive AC 50 Hz: | 24.0 V |
| Rated control supply voltage magnetic drive AC 60 Hz: | 24.0 V |
| Rated control supply voltage magnetic drive DC: | 24.0 V |
| Width of the sensor: | 110.0 mm |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | other |
| Suitable for safety functions: | yes |
| Housing design: | Cuboid |
| Height of the sensor: | 94.0 mm |
| Length of the sensor: | 33.0 mm |
| With escape release: | no |
| With status display: | no |
| Protection class (IP): | IP67K |
| Ambient temperature during operation: | -25.0 to 60.0 °C |
| Housing material: | Plastic |
| Locking force: | 20.0 N |
| Type of locking: | Closed-circuit principle |
| With auxiliary release: | no |
| Housing coating: | other |
Features
Rated operating current Ie at DC-13, 230 V
0.27 A
Rated operating current Ie at DC-13, 125 V
0.55 A
Rated operating current Ie at AC-15, 125 V
3.0 A
HAB
XCSTE7511 PG OEOE Solenoid 24V OFF
Manufacturer
HAN
XCSTE7511
GTIN
3389110825442
Number of contacts as normally open
0.0
Number of contacts as changeover
0.0
Number of contacts as opener
2.0
Number of safety-related auxiliary contacts
0.0
Implementation of the interface
Without
Design of the interface for safety-related communication
Without
Design of the electrical connection
Cable entry PG
Rated operating current Ie at AC-15, 230 V
1.5A
Housing coating
Other
Width of the sensor
110.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Other
Suitable for security functions
Yes
Housing design
Cuboid
Height of the sensor
94.0 mm
Length of the sensor
33.0 mm
With status display
No
IP protection)
IP67K
Ambient temperature during operation
-25.0 to 60.0 °C
Housing material
Plastic
No reviews yet — your comment may be first.