The Harmony XPS Basic safety relays implement basic safety functions. The focus is on classic functions and easy operation with many switching contacts. It can be operated directly without setting and has a realizable safety function. For this purpose, the mechanical break contacts of emergency stop/stop buttons, position or cable pull switches are integrated into the supply circuit of the safety relay. This means that the safety function can be implemented in a single or two-channel (redundant) version. Automatic, manual or monitored start is available on separate inputs for the start function. This safety switching device has 4 safe relay make contacts and 2 relay break contacts as outputs. The supply voltage is 24 VAC/DC and the connections are made via removable screw terminals. Applications up to safety level PL e in category 4 or SIL3 can be implemented. Installation is carried out by snapping onto a top hat rail or screwing onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium eco-label, you can receive detailed information on material content, environmental impact and circular economy that supports your sustainability goals.
| Property | Value |
| Number of outputs, safety-related, instantaneous, contact-based: | 5.0 |
| Safety type according to IEC 61496-1: | 4 |
| Number of outputs, signaling function, delayed, contact-based: | 0.0 |
| Suitable for monitoring position switches: | yes |
| Suitable for monitoring Proximity switches: | no |
| Evaluation of the inputs: | two-channel |
| With TÜV approval: | yes |
| Number of outputs, safety-related, delayed, contact-based: | 0.0 |
| Number of outputs, safety-related, delayed, semiconductor: | 0.0 |
| Suitable for monitoring magnetic switches: | no |
| With UL approval: | no |
| With Muting function: | no |
| Mounting rail mounting possible: | yes |
| Number of outputs, signalling function, undelayed, contact-based: | 0.0 |
| Performance level according to EN ISO 13849-1: | Level e |
| Design: | Basic device |
| Number of outputs, signalling function, delayed, semiconductor: | 0.0 |
| Design of the electrical connection: | screw connection |
| Number of Outputs, safety-related, undelayed, semiconductor: | 0.0 |
| Suitable for monitoring optoelectronic protective devices: | no |
| Number of outputs, signaling function, undelayed, semiconductor: | 0.0 |
| Suitable for monitoring EMERGENCY STOP circuits: | yes |
| Suitable for monitoring valves: | no |
| Suitable for monitoring tactile sensors: | no |
| With approval for BG BIA: | no |
| Width: | 22.5 mm |
| Height: | 100.0 mm |
| Depth: | 120.0 mm |
| With removable terminals: | yes |
| With start input: | yes |
| With feedback loop: | yes |
| SIL according to IEC 61508: | 3 |