XUB optoelectronic sensor, design 18mm, reflective light barrier, switching distance Sn 4m, power supply 12-24V DC, connector M12
| Property | Value |
| Switching distance: | 4000.0 mm |
| Switching distance max.: | 5500.0 mm |
| Reflector ab. min.: | 1000.0 mm |
| Current Imax.: | 100.0 mA |
| Voltage DC: | 12.0 to 24.0 V |
| Button function: | dark switching |
| Protection class (IP): | IP65 |
| Depth: | 60.0 mm |
| Diameter: | 18.0 mm |
| Reaction time: | 1.0 ms |
| Switching frequency: | 500.0 Hz |
| Laser protection class: | without |
| Type of voltage: | AC/DC |
| Housing material: | Plastic |
| With SSI communication interface: | no |
| With AS-Interface communication interface: | no |
| With time function: | no |
| With DeviceNet communication interface: | no |
| Switching function design: | Normally open (NO) |
| With INTERBUS communication interface: | no |
| With analog communication interface: | no |
| With Ethernet communication interface: | no |
| Analog output 4 mA ... 20 mA: | no |
| With other analog output: | no |
| With PROFIBUS communication interface: | no |
| With Reflector: | yes |
| Suitable for safety functions: | no |
| Analog output 0 mA ... 20 mA: | no |
| Analog output -10 V ... +10 V: | no |
| With communication interface SSD: | no |
| With communication interface CANOpen: | no |
| With communication interface RS-485: | no |
| Analog output 0 V ... 10 V: | no |
| Light type: | infrared light |
| Material of the optical surface: | plastic |
| With communication interface RS-422: | no |
| Setting method: | other |
| With communication interface RS-232: | no |
| Number of semiconductor outputs with reporting function: | 1.0 |
| Number of contact-based outputs with reporting function: | 0.0 |
| Number of safe semiconductor outputs: | 1.0 |
| Number of safe contact outputs: | 0.0 |
| Design of the interface for safety-related communication: | other |
| Design of the electrical connection: | M12 connector |
| Design of the switching output: | PNP/PNP |
| Equipment protection class: | Protection class 0 |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | without |
| Housing design: | cylinder, thread |
| Max. Output current at the safe output: | 100.0 mA |
| Ambient temperature: | -25.0 to 55.0 °C |
| Safety type according to IEC 61496-1: | 1 |
| With monitoring function for downstream devices: | no |
| Pre-failure message: | no |
| With restart lock: | no |
Features
Design of the switching function
Normally open (NO)
Switching frequency
500.0 Hz
HAB
XUB1APANM12
Manufacturer
HAN
XUB1APANM12
GTIN
3389110148688
Design of the interface for safety-related communication
Other
Design of the switching output
PNP/PNP
Design of the electrical connection
Connector M12
Diameter
18.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Housing design
Cylinder, thread
Switching distance
4000.0 mm
IP protection)
IP65
Voltage type
AC/DC
Depth
60.0 mm
Ambient temperature
-25.0 to 55.0 °C
Housing material
Plastic