Description
Features
Reviews
XUK optoelectronic sensor, compact design 50x50mm, reflective light barrier, set, switching distance Sn 7m, power supply 24-240V AC/DC, 2m connecting cable
Property | Value |
Switching distance: | 7000.0 mm |
Switching distance max.: | 10000.0 mm |
Reflector ab. min.: | 5000.0 mm |
Current Imax.: | 3000.0 mA |
Voltage AC 50Hz: | 24.0 to 240.0 V |
Voltage AC 60Hz: | 24.0 to 240.0 V |
Voltage DC: | 24.0 to 240.0 V |
Button function: | light switching |
Protection class (IP): | IP65 |
Height: | 50.0 mm |
Width: | 18.0 mm |
Depth: | 50.0 mm |
Response time: | 25.0 ms |
Switching frequency: | 20.0 Hz |
Laser protection class: | without |
Type of voltage: | AC/DC |
Housing material: | Plastic |
With communication interface SSI: | no |
With communication interface AS-Interface: | no |
With time function: | no |
With communication interface DeviceNet: | no |
Execution of the switching function: | Changeover contact (NO/NC) |
With communication interface INTERBUS: | no |
With communication interface Analog: | no |
With communication interface Ethernet: | no |
Analog output 4 mA ... 20 mA: | no |
With other analog output: | no |
With communication interface PROFIBUS: | no |
With reflector: | yes |
Suitable for safety functions: | no |
Analog output 0 mA ... 20 mA: | no |
Analog output -10 V ... +10 V: | no |
With communication interface SSD: | no |
With communication interface CANOpen: | no |
With communication interface RS-485: | no |
Analog output 0 V ... 10 V: | no |
Light type: | Infrared light |
Material of the optical surface: | Plastic |
With communication interface RS-422: | no |
Setting method: | Teach-In |
With communication interface RS-232: | no |
Number of semiconductor outputs with signaling function: | 1.0 |
Number of contact-based outputs with signaling function: | 0.0 |
Number of safe semiconductor outputs: | 0.0 |
Number of safe contact-based outputs: | 0.0 |
Design of the interface for safety-related communication: | other |
Design of the electrical connection: | Cable radial |
Design of the switching output: | Relay contact |
Equipment protection class: | Protection class 0 |
Explosion protection category for gas: | without |
Explosion protection category for dust: | without |
Housing design: | Cuboid |
Max. Output current at the safe output: | 3000.0 mA |
Ambient temperature: | -25.0 to 55.0 °C |
Safety type according to IEC 61496-1: | 1 |
With monitoring function for downstream devices: | no |
Pre-fault message: | no |
With restart lock: | no |
Features
Design of the switching function
Changeover contact (NO/NC)
Switching frequency
20.0 Hz
HAB
XUK1ARCNL2H60
Manufacturer
HAN
XUK1ARCNL2H60
GTIN
3389119037662
Design of the interface for safety-related communication
Other
Design of the switching output
Relay contact
Design of the electrical connection
Cable radial
Width
18.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Housing design
Cuboid
Height
50.0 mm
Switching distance
7000.0 mm
IP protection)
IP65
Voltage type
AC/DC
Depth
50.0 mm
Ambient temperature
-25.0 to 55.0 °C
Housing material
Plastic