XUK optoelectronic sensor, compact design 50x50mm, polarized reflection light barrier, switching distance Sn 5m, power supply 12-24V DC, connector M12
| Property | Value |
| Switching distance: | 5000.0 mm |
| Switching distance max.: | 8000.0 mm |
| Reflector ab. min.: | 1000.0 mm |
| Current Imax.: | 100.0 mA |
| Voltage DC: | 12.0 to 24.0 V |
| Button function: | dark switching |
| Protection class (IP): | IP65 |
| Height: | 50.0 mm |
| Width: | 18.0 mm |
| Depth: | 50.0 mm |
| Response time: | 2.0 ms |
| Switching frequency: | 250.0 Hz |
| Laser protection class: | without |
| Type of voltage: | AC/DC |
| Housing material: | Plastic |
| With communication interface SSI: | no |
| With communication interface AS-Interface: | no |
| With time function: | no |
| With DeviceNet communication interface: | no |
| Execution of the switching function: | Normally open (NO) |
| With INTERBUS communication interface: | no |
| With Analog communication interface: | no |
| With Ethernet communication interface: | no |
| Analog output 4 mA ... 20 mA: | no |
| With other analog output: | no |
| With communication interface PROFIBUS: | no |
| With reflector: | no |
| Suitable for safety functions: | no |
| Analog output 0 mA ... 20 mA: | no |
| Analog output -10 V ... +10 V: | no |
| With communication interface SSD: | no |
| With communication interface CANOpen: | no |
| With communication interface RS-485: | no |
| Analog output 0 V ... 10 V: | no |
| Light type: | polarized red light |
| Material of the optical surface: | plastic |
| With communication interface RS-422: | no |
| Setting method: | other |
| With communication interface RS-232: | no |
| Number of semiconductor outputs with reporting function: | 1.0 |
| Number of contact outputs with signaling function: | 0.0 |
| Number of safe semiconductor outputs: | 0.0 |
| Number of safe contact outputs: | 0.0 |
| Design of the interface for safety-related communication: | other |
| Design of the electrical connection: | M12 connector |
| Design of the switching output: | PNP/PNP |
| Equipment protection class: | Protection class 0 |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | without |
| Housing design: | Cuboid |
| Max. Output current at the safe output: | 100.0 mA |
| Ambient temperature: | -25.0 to 55.0 °C |
| Safety type according to IEC 61496-1: | 1 |
| With monitoring function for downstream devices: | no |
| Pre-failure message: | no |
| With restart lock: | no |
Features
Design of the switching function
Normally open (NO)
Switching frequency
250.0 Hz
HAB
XUK9APANM12
Manufacturer
HAN
XUK9APANM12
GTIN
3389110163957
Design of the interface for safety-related communication
Other
Design of the switching output
PNP/PNP
Design of the electrical connection
Connector M12
Width
18.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Housing design
Cuboid
Height
50.0 mm
Switching distance
5000.0 mm
IP protection)
IP65
Voltage type
AC/DC
Depth
50.0 mm
Ambient temperature
-25.0 to 55.0 °C
Housing material
Plastic