Description
Features
Reviews
Reflection light barriers OsiSense XUX. Switching distance Sn 14m. 24V-240V AC/DC, dimensions 92 x30.5 x 71, terminal.
| Property | Value |
| Switching distance: | 14000.0 mm |
| Switching distance max.: | 20000.0 mm |
| Reflector ab. min.: | 5000.0 mm |
| Current Imax.: | 3000.0 mA |
| Voltage AC 50Hz: | 24.0 to 240.0 V |
| Voltage AC 60Hz: | 24.0 to 240.0 V |
| Voltage DC: | 24.0 to 240.0 V |
| Button function: | dark switching |
| Protection class (IP): | IP65 |
| Height: | 92.0 mm |
| Width: | 31.0 mm |
| Depth: | 77.0 mm |
| Response time: | 25.0 ms |
| Switching frequency: | 20.0 Hz |
| Laser protection class: | without |
| Type of voltage: | AC/DC |
| Housing material: | Plastic |
| With communication interface SSI: | no |
| With communication interface AS-Interface: | no |
| With time function: | no |
| With communication interface DeviceNet: | no |
| Execution of the switching function: | Changeover contact (NO/NC) |
| With communication interface INTERBUS: | no |
| With communication interface Analog: | no |
| With communication interface Ethernet: | no |
| Analog output 4 mA ... 20 mA: | no |
| With other analog output: | no |
| With communication interface PROFIBUS: | no |
| With reflector: | no |
| Suitable for safety functions: | no |
| Analog output 0 mA ... 20 mA: | no |
| Analog output -10 V ... +10 V: | no |
| With communication interface SSD: | no |
| With communication interface CANOpen: | no |
| With communication interface RS-485: | no |
| Analog output 0 V ... 10 V: | no |
| Light type: | infrared light |
| Material of the optical surface: | plastic |
| With communication interface RS-422: | no |
| Setting method: | manual setting |
| With communication interface RS-232: | no |
| Number of semiconductor outputs with signaling function: | 0.0 |
| Number of contact-based outputs with signaling function: | 1.0 |
| Number of safe semiconductor outputs: | 0.0 |
| Number of safe contact-based outputs: | 0.0 |
| Design of the interface for safety-related communication: | other |
| Design of the electrical connection: | other |
| Design of the switching output: | relay contact |
| Equipment protection class: | Protection class 0 |
| Explosion protection category for gas: | without |
| Explosion protection category for dust: | without |
| Housing design: | cuboid |
| Max. Output current at the safe output: | 100.0 mA |
| Ambient temperature: | -25.0 to 55.0 °C |
| Safety type according to IEC 61496-1: | 1 |
| With monitoring function for downstream devices: | no |
| Pre-failure message: | no |
| With restart lock: | no |
Features
Design of the switching function
Changeover contact (NO/NC)
Switching frequency
20.0 Hz
HAB
XUX1ARCNT16 Reflex
Manufacturer
HAN
XUX1ARCNT16
GTIN
3389110168419
Design of the interface for safety-related communication
Other
Design of the switching output
Relay contact
Design of the electrical connection
Other
Width
31.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Housing design
Cuboid
Height
92.0 mm
Switching distance
14000.0 mm
IP protection)
IP65
Voltage type
AC/DC
Depth
77.0 mm
Ambient temperature
-25.0 to 55.0 °C
Housing material
Plastic