Description
Features
Reviews
XUX optoelectronic sensor, compact design 92x71mm, receiver, switching distance Sn 40m, power supply 12-24V DC, connector M12
| Property | Value |
| Design of the switching output: | PNP/PNP |
| Rated switching distance: | 40000.0 mm |
| Voltage DC: | 12.0 to 24.0 V |
| Current Imax.: | 100.0 mA |
| Button function: | dark switching |
| Protection class (IP): | IP65 |
| Length: | 77.0 mm |
| Width: | 30.0 mm |
| Height: | 92.0 mm |
| Design of the interface for safety-related communication: | other |
| Explosion protection category for gas: | without |
| Number of safe contact-based outputs: | 0.0 |
| Design of the electrical connection: | M12 connector |
| Laser protection class: | other |
| With INTERBUS communication interface: | no |
| With RS-485 communication interface: | no |
| With Ethernet communication interface: | no |
| With reflector: | no |
| Max. Output current at the safe output: | 100.0 mA |
| Analog output 4 mA ... 20 mA: | no |
| Housing design: | Cuboid |
| With SSD communication interface: | no |
| Pre-failure message: | no |
| With CANOpen communication interface: | no |
| With restart lock: | no |
| Analog output -10 V ... +10 V: | no |
| Housing material: | Plastic |
| Analog output 0 V ... 10 V: | no |
| Light type: | Infrared light |
| With analog communication interface: | no |
| With PROFIBUS communication interface: | no |
| Switching function design: | Normally open (NO) |
| Safety type according to IEC 61496-1: | 1 |
| Explosion protection category for dust: | none |
| Min. reflector distance: | 30000.0 mm |
| Max. Opening angle: | 0.0 ° |
| Material of the optical surface: | Plastic |
| Number of contact outputs with signaling function: | 0.0 |
| Suitable for safety functions: | no |
| Analog output 0 mA ... 20 mA: | no |
| Equipment protection class: | Protection class 0 |
| With communication interface RS-422: | no |
| Max. Switching distance: | 60000.0 mm |
| Switching frequency: | 250.0 Hz |
| Number of safe semiconductor outputs: | 0.0 |
| With communication interface AS-Interface: | no |
| Response time: | 2.0 ms |
| With other analog output: | no |
| With monitoring function of downstream devices: | no |
| Scope of delivery of the one-way system: | Receiver |
| With RS-232 communication interface: | no |
| Number of semiconductor outputs with reporting function: | 1.0 |
| With SSI communication interface: | no |
| With DeviceNet communication interface: | no |
| Cable sheath material: | other |
| Ambient temperature: | -25.0 to 55.0 °C |
| Setting method: | Teach-In |
| Voltage type: | AC/DC |
| With time function: | no |
Features
Design of the switching function
Normally open (NO)
Switching frequency
250.0 Hz
HAB
XUX2APANM12R Receiver
Manufacturer
HAN
XUX2APANM12R
GTIN
3389110170290
Design of the interface for safety-related communication
Other
Design of the switching output
PNP/PNP
Design of the electrical connection
Connector M12
Width
30.0 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Housing design
Cuboid
Height
92.0 mm
Length
77.0 mm
IP protection)
IP65
Voltage type
AC/DC
Ambient temperature
-25.0 to 55.0 °C
Housing material
Plastic
No reviews yet — your comment may be first.