Description
Features
Reviews
Reflection light barrier OsiSense XU. Complete set, consisting of: reflection light barrier, reflector (diameter: 80 mm for XUJ, 50 x 50 mm for XUL, XUK, XUX), mounting bracket, assembly instructions, switching distance Sn 11m. 24V-240V AC/DC, dimensions 92 x30.5 x 71, terminal block. IP67.
| Property | Value |
| Range of the protective field: | 11 m |
| Design of the switching output: | other |
| Rated switching distance: | 11000.0 mm |
| Voltage AC 50Hz: | 24.0 to 240.0 V |
| Voltage AC 60Hz: | 24.0 to 240.0 V |
| Voltage DC: | 24.0 to 240.0 V |
| Button function: | light/dark switching |
| Protection class (IP): | IP65 |
| Width: | 31.0 mm |
| Height: | 92.0 mm |
| Design of the interface for safety-related communication: | other |
| Explosion protection category for gas: | other |
| Number of safe contact-based outputs: | 0.0 |
| Design of the electrical connection: | Screw connection |
| Laser protection class: | other |
| With communication interface INTERBUS: | no |
| With communication interface RS-485: | no |
| With communication interface Ethernet: | no |
| With reflector: | no |
| Analog output 4 mA ... 20 mA: | no |
| Housing design: | Cylinder, thread |
| With communication interface SSD: | no |
| Pre-failure warning: | no |
| With communication interface CANOpen: | no |
| With restart lock: | no |
| Analog output -10 V ... +10 V: | no |
| Housing material: | Plastic |
| Analog output 0 V ... 10 V: | no |
| Light type: | Multi-colour LED |
| With analogue communication interface: | no |
| With PROFIBUS communication interface: | no |
| Switching function design: | Changeover contact (NO/NC) |
| Safety type according to IEC 61496-1: | 1 |
| Explosion protection category for dust: | other |
| Material of the optical surface: | Plastic |
| Number of contact outputs with Reporting function: | 1.0 |
| Suitable for safety functions: | no |
| Analog output 0 mA ... 20 mA: | no |
| Equipment protection class: | Protection class 0 |
| With communication interface RS-422: | no |
| Max. Switching distance: | 15000.0 mm |
| Number of safe semiconductor outputs: | 0.0 |
| With AS-Interface communication interface: | no |
| With other analog output: | no |
| With monitoring function for downstream devices: | no |
| With RS-232 communication interface: | no |
| With SSI communication interface: | no |
| With DeviceNet communication interface: | no |
| Ambient temperature: | -25.0 to 55.0 °C |
| Setting method: | other |
| Voltage type: | AC/DC |
| With time function: | no |
Features
Design of the switching function
Changeover contact (NO/NC)
HAB
XUX9ARCNT16S49 24-240VAC/DC
Manufacturer
HAN
XUX9ARCNT16S49
GTIN
3389119622936
Design of the interface for safety-related communication
Other
Design of the switching output
Other
Design of the electrical connection
Screw connection
Width
31.0 mm
Explosion protection category for gas
Other
Explosion protection category for dust
Other
Suitable for security functions
No
Housing design
Cylinder, thread
Height
92.0 mm
IP protection)
IP65
Voltage type
AC/DC
Ambient temperature
-25.0 to 55.0 °C
Housing material
Plastic
No reviews yet — your comment may be first.
All reviews 0