SIRIUS compact starter direct starter 690 V AC/DC 24 V 50...60 Hz 0.32...1.25 A IP20 Main circuit connection: plug-in, without terminals Auxiliary circuit connection: spring-loaded connection SIRIUS 3RA61 compact starter for direct starting of standard three-phase motors up to 32 A.The devices combine the functions of circuit breakers, contactors and electronic overload relays and have a very high level of operational reliability. A low variance simplifies logistics. The compact design saves space in the control cabinet. Removable terminals make replacement easy. The devices are approved worldwide (e.g. IEC and UL/CSA).The compact starters are available as direct or reversing starters and are available with various setting ranges. Designed for AC/DC operation, they are available with screw, spring-loaded connection or without terminals. In addition to the communication connection via AS-Interface, the 3RA68 feed-in system and auxiliary contacts as well as terminals are available as accessories. Simple, efficient, always up-to-date - the SIRIUS modular system.
Property | Value |
Overload release current setting: | 0.32 to 1.25 A |
Voltage type for operation: | AC/DC |
Rated operating power at AC-3, 400 V: | 0.37 kW |
Rated operating current Ie: | 1.25 A |
Rated control supply voltage Us at AC 50 Hz: | 24 V |
Rated control supply voltage Us at AC 60 Hz: | 24 V |
Rated control supply voltage Us at DC: | 24 V |
With short-circuit release: | yes |
Supports protocol for SafetyBUS p: | no |
Number of auxiliary contacts as normally closed contacts: | 1 |
Supports protocol for INTERBUS: | no |
Supports protocol for CAN: | no |
Supports protocol for ASI: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for Data-Highway: | no |
Supports protocol for MODBUS: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for TCP/IP: | no |
Supports protocol for SERCOS: | no |
Temperature compensated overload protection: | no |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | no |
Supports protocol for PROFINET CBA: | no |
Rated operating current at AC-3, 400 V: | 1.25 A |
Supports protocol for SUCONET: | no |
DIN rail mounting possible: | yes |
Supports protocol for PROFIsafe: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for LON: | no |
Supports protocol for DeviceNet Safety: | no |
Ambient temperature, upper limit without restrictions: | 60 °C |
Supports protocol for PROFIBUS: | no |
Number of auxiliary contacts as normally open: | 1 |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for INTERBUS-Safety: | no |
With transformer: | no |
Number of command points: | 1 |
Suitable for EMERGENCY STOP: | no |
Number of indicator lights: | 2 |
External reset possible: | yes |
With fuse: | no |
Width: | 45 mm |
Height: | 191 mm |
Depth: | 165 mm |