SIRIUS motor starter M200D technology module reversing starter electronically switching AC-3.5.5 kW / 400 V 1.5 A...12.00 A electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 400 V AC 4DI / 2DO Han Q4/2 - Han Q8/0 via communication module 3RK1305* can be used on PROFIBUS or PROFINET Motor starter SIRIUS M200D for starting, monitoring and protecting motors and consumers for use in the field and for fully TIA-integrated, highly automated applications, e.g. in conveyor technology. The robust motor starters with a high degree of protection for PROFIBUS/PROFINET communication are easy to configure and can be installed and put into operation quickly and error-free thanks to the modular starter concept and pre-assembled cables. A cost-effective and quick device replacement is possible in the event of servicing thanks to modularity and automatic reparameterization. The integration of associated sensors is supported. The use of the devices increases system availability thanks to a comprehensive diagnostic concept and sophisticated system monitoring. The Motor Starter ES software is available for project planning, commissioning, operation and diagnostics. PROFIenergy supports active and efficient energy management. The motor starters are approved worldwide (e.g. IEC and UL/CSA) and IE3/IE4ready. Available as direct or reversing starters with various motor current ranges, optionally electromechanical or electronic switching, optionally with brake control or local hand-held on-site control device. A communication module is also required for communication via PROFINET or PROFIBUS. A comprehensive range of accessories suitable for all M200D motor starters is available, e.g. pre-assembled cables.SIRIUS M200D - The robust motor starter for decentralized drive solutions.
Property | Value |
Overload release current setting: | 1.5 to 12 A |
Voltage type for actuation: | DC |
Rated operating power at AC-3, 400 V: | 5.5 kW |
Rated operating current Ie: | 12 A |
Rated control supply voltage Us at DC: | 20.4 to 28.8 V |
With short-circuit release: | yes |
Supports protocol for SafetyBUS p: | no |
Supports protocol for INTERBUS: | no |
Supports protocol for CAN: | no |
Supports protocol for ASI: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for Data highway: | no |
Supports protocol for MODBUS: | no |
Supports protocol for PROFINET IO: | yes |
Supports protocol for TCP/IP: | no |
Supports protocol for SERCOS: | no |
Temperature compensated overload protection: | yes |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other Bus systems: | no |
Supports protocol for PROFINET CBA: | no |
Rated operating current at AC-3, 400 V: | 12 A |
Supports protocol for SUCONET: | no |
Mounting rail mounting possible: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for LON: | no |
Supports protocol for DeviceNet Safety: | no |
Ambient temperature, upper limit without restrictions: | 40 °C |
Conditional rated short-circuit current, allocation type 1, 480 Y/277 V: | 20000 A |
Rated operating power at AC-3, 230 V, 3-phase: | 3 kW |
Supports protocol for PROFIBUS: | yes |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for INTERBUS-Safety: | no |
Rated power, 460 V, 60 Hz, 3-phase: | 5.5 kW |
With transformer: | no |
Number of command points: | 4 |
Suitable for EMERGENCY STOP: | no |
Assignment type according to IEC 60947-4-3: | Class 1 |
Number of indicator lights: | 12 |
External reset possible: | yes |
With fuse: | yes |
Width: | 294 mm |
Height: | 215 mm |
Depth: | 148 mm |