Circuit breaker 3VA6 UL Frame 400 switching capacity class C 100kA @ 480V 3-pole, system protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N-conductor protection optionally with external current transformer, up to 160% ground fault protection Ig=0.2...1 x In, tg=0.05-0.8s without connection 3VA6 molded case circuit breaker with ETU 5 series for system protection, UL approval. The 3VA UL molded case circuit breakers from Siemens as an important component of the SENTRON protection components for industrial applications as well as for applications in the infrastructure sector offer effective system and starter protection through safe shutdown in the event of overload and short circuit. The 3VA sets standards in terms of flexibility and modular accessories. The 3VA UL molded case circuit breaker also offers the best conditions for machine and switchgear manufacturers exporting worldwide. In addition to the IEC standard, the two series 3VA5 and 3VA6 also meet the UL standard. All functions can therefore be used and deployed worldwide for systems. This variant of the 3VA molded case circuit breaker is characterized above all by: 1. Compact design. 2. Available as a variant for system protection. 3. Available as a 3- and 4-pole version. 4. Four switching capacity classes from 35 kA to 150 kA at 480 V. 5. Depending on the size: Rated current 40 A.600 A. 6. Installation in fixed installation, plug-in technology, withdrawable technology possible. 7. The series has an electronic overcurrent release. 8. Has an integrated display for measuring value display. 9. Optional communication connection via Modbus TCP, Modbus RTU, PROFINET and PROFIBUS. 10. Modular and easy-to-install internal accessories with a wide range of functions. www.siemens.de/3VA. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe, efficient electrical infrastructure in buildings and industry.
Property | Value |
Rated continuous current Iu: | 400 A |
Number of poles: | 3 |
Degree of protection (IP): | IP40 |
Overload release current setting: | 160 to 400 A |
Setting range of the short-time delayed short-circuit release: | 240 to 4000 A |
Setting range of the instantaneous short-circuit release: | 600 A |
Rated voltage: | 690 V |
Rated short-circuit breaking current Icu at 400 V, 50 Hz: | 110 kA |
Suitable for DIN rail mounting: | yes |
Integrated earth fault protection: | yes |
Motor drive integrated: | no |
Motor drive optional: | yes |
With trip detector: | no |
Complete device with protection unit: | yes |
DIN rail mounting optional: | yes |