SIPLUS S7-300 CPU 317F-2DP based on 6ES7317-6FF04-0AB0 with conformal coating, -25.+60°C, central processing unit with 1.5MByte RAM, 1st interface MPI/DP 12MBit/s, 2nd interface DP master/slave, Micro Memory Card required, can be used with software package S7 Distributed Safety from V5.2 SP1 The SIPLUS extreme variant also protects the automation components from harsh environmental conditions, such as particularly high and low temperatures, corrosive gases, condensation, frost and biologically, chemically and mechanically active substances, such as can occur in control cabinets or container solutions close to production. This means that your medium and demanding automation tasks are reliably protected and offer additional investment security.
Property | Value |
Height: | 125 mm |
Width: | 40 mm |
Depth: | 130 mm |
Wireless standard WLAN 802.11: | no |
With display: | no |
Wireless standard Bluetooth: | no |
Suitable for Safety functions: | yes |
Supports protocol for INTERBUS: | no |
Front installation possible: | no |
Rack mounting possible: | no |
Performance level according to EN ISO 13849-1: | Level e |
IO-Link Master: | no |
Redundancy capability: | yes |
Type of supply voltage: | DC |
Supply voltage for DC: | 19.2 to 28.8 V |
Memory type: | RAM |
Wall/direct mounting possible: | no |
System component: | yes |
Rail mounting possible: | yes |
Processing time (1K, binary instruction): | 0.025 ms |
Supports protocol for DeviceNet Safety: | no |
Supports Protocol for CAN: | no |
Supports Protocol for SERCOS: | no |
Supports Protocol for KNX: | no |
Supports Protocol for SUCONET: | no |
Supports Protocol for SafetyBUS p: | no |
Supports Protocol for MODBUS: | no |
Supports Protocol for PROFINET IO: | no |
Supports Protocol for EtherNet/IP: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for Data-Highway: | no |
Supports protocol for PROFINET CBA: | no |
Supports protocol for other bus systems: | yes |
Supports protocol for TCP/IP: | no |
Supports protocol for PROFIBUS: | yes |
Supports protocol for INTERBUS-Safety: | no |
Supports protocol for ASI: | no |
Supports protocol for LON: | no |
Design: | modular |
Memory size: | 1536 kByte |
Number of HW interfaces serial RS-485: | 2 |
With optical interface: | no |
Program memory expansion possible: | no |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Wireless standard GSM: | no |
Wireless standard GPRS: | no |
SIL according to IEC 61508: | 3 |
Radio standard UMTS: | no |