SIMATIC ET 200SP, digital input module, DI 16x 24V DC standard, input type 3 (IEC 61131), sink input, (PNP, P-reading), packaging unit: 10 pieces, suitable for BU type A0, color code CC00, input delay 0, 05..20ms Module diagnostics for: wire break, supply voltage The SIMATIC ET 200SP is a modular, scalable and highly flexible, decentralized I/O system. Due to its small footprint, it is particularly designed for installation in small control boxes close to the machine. The modules can either be plugged directly into an ET 200SP CPU or connected to a central controller via PROFINET or PROFIBUS. The SIMATIC ET 200SP can be expanded with up to 64 I/O modules, which can be plugged in in any combination. The system offers a very extensive range of modules. Many modules are also available in different versions, which significantly improves scalability in terms of functionality and price. In addition to modules with standard functionality (ST), there are also modules with an extended range of functions and diagnostics (HF High Feature / HS High Speed). Modules with basic functionality (BA) are available for price-sensitive applications. The advantage of the ET 200SP system lies in its ease of use, for example through the free choice of PROFINET connection technology via the bus adapter, tool-free wiring using push-in technology, improved accessibility of the wiring through a new arrangement of the spring openers next to the associated conductor opening and the channel-specific diagnostic functions. The availability and productivity of the machine are ensured by the option of changing modules and terminal boxes during operation, known as hot swapping. The scalable and cost-optimized configuration of an ET 200SP station is guaranteed by the comprehensive range of signal modules. In addition to digital and analog input and output modules, fail-safe variants are also available for applications up to SIL 3 / PLe. This also applies to the integrated motor starters, which are suitable for motors up to 5.5 kW. Energy meters for measuring and analyzing energy consumption, IO-Link Master (V1.1.) and many other communication and technology modules enable the system to adapt to any automation task. The available accessories for ET 200SP range from color and reference labeling plates to labeling strips for the individual modules and ensure maximum clarity in the control cabinet.
Property | Value |
Protection class (IP): | IP20 |
Type of supply voltage: | DC |
Permissible voltage at the input: | -30 to 30 V |
Input current for signal 1: | 2.5 mA |
Width: | 15 mm |
Height: | 73 mm |
Depth: | 58 mm |
Mounting rail mounting possible: | yes |
Wireless standard Bluetooth: | no |
Wireless standard WLAN 802.11: | no |
Supports protocol for INTERBUS: | no |
Supports protocol for PROFIBUS: | no |
Supports protocol for ASI: | no |
Rack mounting possible: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for PROFINET CBA: | no |
Supply voltage for DC: | 19.2 to 28.8 V |
Supports protocol for Data Highway: | no |
Supports protocol for SafetyBUS p: | no |
IO-Link Master: | no |
Supports protocol for MODBUS: | no |
Wall/direct mounting possible: | no |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | no |
Supports protocol for SERCOS: | no |
Supports protocol for KNX: | no |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for SUCONET: | no |
Front installation possible: | no |
Suitable for safety functions: | no |
Supports protocol for TCP/IP: | no |
Supports protocol for CAN: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Type of input voltage: | DC |
Delay time for signal change: | 0.05 to 20 ms |
Field bus connection possible via separate bus coupler: | yes |
Supports protocol for LON: | no |
Supports protocol for INTERBUS-Safety: | no |
System component: | yes |
With optical interface: | no |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Explosion protection category for gas: | ATEX gas explosion protection, cat. 3G |
Radio standard GSM: | no |
Number of digital inputs: | 16 |
Digital inputs configurable: | yes |
Radio standard GPRS: | no |
Radio standard UMTS: | no |