SIMATIC ET 200AL, DI 8x 24VDC, 8XM8, protection class IP67 SIMATIC ET 200AL, DI 8x 24VDC, 8XM8, protection class IP67 SIMATIC ET 200 AL is an IO system in block construction with a high protection class IP65/67, a particularly compact design and low space requirements and weight. It is specially designed for distributed control electronics in confined spaces and when moving and is quickly and conveniently configured and commissioned via the TIA Portal. Standard modules can be switched off in groups for safety reasons. The peripheral modules are the interface of the SIMATIC ET 200AL to the process. They are available as digital and analog input and output modules and as mixed modules (digital). The sensors are connected via M8 or M12 connection technology. The modules can be connected to PROFINET or PROFIBUS or integrated into SIMATIC ET 200SP. SIMATIC ET 200AL - for the easiest installation anywhere
Property | Value |
Protection class (IP): | IP65/IP67 |
Type of supply voltage: | DC |
Permissible voltage at input: | -30 to 30 V |
Input current for signal 1: | 3.2 mA |
Width: | 30 mm |
Height: | 159 mm |
Depth: | 40 mm |
Deck rail mounting possible: | yes |
Wireless standard Bluetooth: | no |
Wireless standard WLAN 802.11: | no |
Supports protocol for INTERBUS: | no |
Supports protocol for PROFIBUS: | no |
Supports protocol for ASI: | no |
Rack mounting possible: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for PROFINET CBA: | no |
Supply voltage for DC: | 20.4 to 28.8 V |
Supports protocol for Data-Highway: | no |
Supports protocol for SafetyBUS p: | no |
IO-Link Master: | no |
Supports protocol for MODBUS: | no |
Wall/direct mounting possible: | yes |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | no |
Supports protocol for SERCOS: | no |
Supports protocol for KNX: | no |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for SUCONET: | no |
Front installation possible: | yes |
Suitable for safety functions: | no |
Supports protocol for TCP/IP: | no |
Supports protocol for CAN: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Type of input voltage: | DC |
Delay time for signal change: | 1.2 to 4.8 ms |
Field bus connection via separate bus coupler possible: | yes |
Supports protocol for LON: | no |
Supports protocol for INTERBUS-Safety: | no |
System component: | yes |
With optical interface: | no |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Radio standard GSM: | no |
Number of digital inputs: | 8 |
Digital inputs configurable: | yes |
Radio standard GPRS: | no |
Radio standard UMTS: | no |