SIMATIC DP, ET 200ECO PN, 16DI DC 24V 8xM12, double assignment, protection class IP67 The SIMATIC ET 200eco PN is a compact block I/O with PROFINET connection in protection class IP65/67 for installation directly on the machine without a control cabinet. Thanks to the fully encapsulated zinc die-cast housing, the ET 200eco PN is mechanically very robust and resistant to vibrations, dust, oil and moisture and is therefore also suitable for outdoor use. Thanks to the ATEX approval, the ET 200eco PN can also be used in potentially explosive areas up to Zone 2. Thanks to its excellent robustness, it can be used in a wide range of areas, particularly in mechanical engineering and the automotive industry, and in particular on tool changing machines. In addition to digital and analog input and output modules in various versions (including current, voltage, temperature and resistance measurements), the portfolio also includes IO-Link masters and a fail-safe module for connecting sensors and actuators up to SIL 3 / PLe. If required, the outputs of the standard modules can also be switched off in a fail-safe manner up to SIL 2.
Property | Value |
Protection class (IP): | IP65/IP67 |
Type of supply voltage: | DC |
Permissible voltage at the input: | -3 to 30 V |
Input current for signal 1: | 7 mA |
Width: | 60 mm |
Height: | 175 mm |
Depth: | 49 mm |
Mounting rail mounting possible: | yes |
Wireless standard Bluetooth: | no |
Wireless standard WLAN 802.11: | no |
Supports protocol for INTERBUS: | no |
Supports protocol for PROFIBUS: | no |
Supports protocol for ASI: | no |
Rack mounting possible: | no |
Supports protocol for PROFINET IO: | yes |
Supports protocol for PROFIsafe: | no |
Supports protocol for PROFINET CBA: | no |
Supply voltage for DC: | 20.4 to 28.8 V |
Supports protocol for Data Highway: | no |
Supports protocol for SafetyBUS p: | no |
IO-Link Master: | no |
Supports protocol for MODBUS: | no |
Wall/direct mounting possible: | yes |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | no |
Supports protocol for SERCOS: | no |
Supports protocol for KNX: | no |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for SUCONET: | no |
Front installation possible: | yes |
Number of PROFINET interfaces: | 1 |
Suitable for safety functions: | no |
Supports protocol for TCP/IP: | no |
Supports protocol for CAN: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Type of input voltage: | DC |
Delay time for signal change: | 1.2 to 4.8 ms |
Field bus connection possible via separate bus coupler: | no |
Supports protocol for LON: | no |
Supports protocol for INTERBUS-Safety: | no |
System component: | yes |
With optical interface: | no |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Explosion protection category for gas: | ATEX gas explosion protection, cat. 3G |
Explosion protection category for dust: | ATEX dust explosion protection, cat. 3D |
Radio standard GSM: | no |
Number of digital inputs: | 16 |
Digital inputs configurable: | yes |
Radio standard GPRS: | no |
Radio standard UMTS: | no |