SINAMICS G120C Rated power: 55.0kW with 150% overload for 3 sec. 3AC380-480V+10/-20% 47-63Hz unfiltered I/O interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integrated Fieldbus integrated:PROFINET-PN Protection class IP20/UL Open Type Size: FSE 551x 275x 237 (HxWxD) external 24V frequency converter SINAMICS G120C the compact and versatile frequency converter with optimal functionality for the requirements of different applications, such as for conveyor belts, mixers, pumps, fans and compressors. The already integrated certified safety function Safe Torque Off (STO), STO via terminal/with PROFIsafe, means that additional external components are not required. Operation/commissioning is quick and easy using a PC via USB or a Basic Operator Control Panel or Intelligent Operator Panel. The drives can be networked using standard fieldbus systems (PROFINET, PROFIBUS) and there is a card slot for cloning parameter sets for intuitive series commissioning. To increase energy efficiency, the converter is equipped with a precise, energy-optimized SLVC vector control and has an automatic flux reduction. The SINAMICS G120C covers the three-phase voltage range between 380 V and 480 V and is available in seven sizes with a power range from 0.55 kW to 132 kW. The SINAMICS G120C frequency converter can be individually adapted to the user's requirements using various options such as connection cables, line filters, braking resistors, line reactors and other accessories. The variable-speed devices are an integral part of Totally Integrated Automation (TIA) and work optimally with SIMATIC controllers, for example. SINAMICS - simply my drive.
Property | Value |
Protection class (IP): | IP20 |
Number of PROFINET interfaces: | 2 |
Mains voltage: | 380 to 480 V |
Number of other HW interfaces: | 6 |
Max. Output frequency: | 550 Hz |
Use in industrial areas permitted: | no |
Height: | 551 mm |
Width: | 275 mm |
Depth: | 237 mm |
Type of converter: | U-converter |
Max. output power with linear load at rated output voltage: | 45 kW |
Supports protocol for data highway: | no |
4-quadrant operation possible: | no |
With optical interface: | no |
Supports protocol for LON: | no |
Relative symmetrical mains voltage tolerance: | -20 % |
Supports protocol for AS-Interface Safety at Work: | no |
Brake chopper integrated: | yes |
Number of input phases: | 3 |
Supports protocol for TCP/IP: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for PROFINET IO: | yes |
Supports protocol for PROFIBUS: | no |
Supports protocol for EtherNet/IP: | yes |
Supports protocol for INTERBUS Safety: | no |
Supports protocol for SUCONET: | no |
Supports protocol for CAN: | no |
Supports protocol for KNX: | no |
Use in residential and commercial areas permitted: | no |
Supports protocol for INTERBUS: | no |
Number of HW interfaces serial RS-232: | 1 |
Number of HW interfaces serial TTY: | 1 |
Supports protocol for other bus systems: | yes |
Supports protocol for ASI: | no |
Supports protocol for SafetyBUS p: | no |
Supports protocol for MODBUS: | no |
Supports protocol for PROFIsafe: | yes |
Supports protocol for DeviceNet Safety: | no |
Number of HW interfaces Industrial Ethernet: | 2 |
Relative symmetrical mains frequency tolerance: | 5 % |
Supports protocol for SERCOS: | no |
Number of output phases: | 3 |
Supports protocol for PROFINET CBA: | no |
Supports protocol for Foundation Fieldbus: | no |
Max. delivered power at square. Load at rated output voltage: | 55 kW |
Number of HW interfaces USB: | 1 |
With PC connection: | yes |
Nominal output current I2N: | 103 A |
Max. Output voltage: | 480 V |
Number of analog outputs: | 1 |
Number of analog inputs: | 1 |
Number of digital outputs: | 2 |
Number of digital inputs: | 6 |
Supports protocol for BACnet: | no |