SINAMICS S210 Input voltage 3AC 200-480V 4 -10%/+10% 12.9A 45-66Hz Output voltage: 6 0-input V 12.0A 0-550Hz Motor: 5.0 kW Protection class: IP20 Frame Size C 105 x 322 x 223 (WxHxD) Servo converter SINAMICS S210, the single-axis servo drive for highly dynamic applications for packaging machines, in handling systems as well as in wood and plastic processing or in digital printing. The servo converter SINAMICS S210 is connected to SIMOTICS S-1FK2 synchronous servo motors. Connection to a higher-level control with PROFINET RT/IRT. This means that SIMATIC S7 (shortened engineering time with SIMATIC S7-1500/T-CPU) and SIMOTION in particular can be used as controllers. The S210 is flexible, versatile and can be used worldwide (with all common approvals, UL-validated for North America). The S210 works with servo control with/without Dynamic Servo Control (DSC) and has a torque setpoint limitation. An integrated one-cable interface OCC (One Cable Connection) enables the convenient connection of a SIMOTICS S-1FK2 motor with just one cable; no other motors need to be connected. The integrated web server allows for very simple commissioning. The automatic detection of motor and encoder makes operation easier (e.g. automatic controller optimization with one-button tuning). Errors and warnings are shown on the display under the front flap, and comprehensive diagnostics with plain text messages are possible via the integrated web server. Integrated safety functions enable highly effective protection of people and machines. Safety Integrated Basic functions are included as standard. In addition, the Safety Integrated Extended functions are optionally available. SINAMICS S210 is supplied with painted or partially painted modules as standard, so that the sensitive SMD components are protected from dust, moisture, etc. The servo converters are available in a single-phase voltage range from 200 V to 240 V, in a power range from 0.1 kW to 0.75 kW and in frame sizes FSA to FSC. The three-phase converters are available in a voltage range from 200 V to 480 V and a power range from 0.4 kW to 7.0 kW in frame sizes FSA to FSC. In the devices of the 3-AC series, the intermediate circuits of up to six converters can be coupled. This enables energy to be balanced between the axes. The SINAMICS S210 can be individually adapted to requirements thanks to various options. The converters are supplied with a shield plate and push-in connectors (without memory card). SINAMICS - simply my drive.
Property | Value |
Protection class (IP): | IP20 |
Number of PROFINET interfaces: | 2 |
Mains voltage: | 480 V |
Use in industrial areas permitted: | yes |
Height: | 322.0 mm |
Width: | 105.0 mm |
Depth: | 223.0 mm |
Max. output power with linear load at rated output voltage: | 5.0 kW |
Supports protocol for data highway: | no |
4-quadrant operation possible: | no |
With optical interface: | no |
Supports protocol for LON: | no |
Relative symmetrical mains voltage tolerance: | -10 % |
Supports protocol for AS-Interface Safety at Work: | no |
Brake chopper integrated: | yes |
Number of input phases: | 3 |
Supports protocol for TCP/IP: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for PROFINET IO: | yes |
Supports protocol for PROFIBUS: | no |
Supports protocol for EtherNet/IP: | no |
Supports protocol for INTERBUS-Safety: | no |
Supports protocol for SUCONET: | no |
Supports protocol for CAN: | no |
Supports protocol for KNX: | no |
Use in residential and commercial areas permitted: | no |
Supports protocol for INTERBUS: | no |
Supports protocol for other bus systems: | no |
Supports protocol for ASI: | no |
Supports protocol for SafetyBUS p: | no |
Supports protocol for MODBUS: | no |
With control element: | no |
Supports protocol for PROFIsafe: | yes |
Supports protocol for DeviceNet Safety: | no |
Number of HW interfaces Industrial Ethernet: | 3 |
Relative symmetrical mains frequency tolerance: | -10 % |
Supports protocol for SERCOS: | no |
Number of output phases: | 3 |
Supports protocol for PROFINET CBA: | no |
Supports protocol for Foundation Fieldbus: | no |
With PC connection: | yes |
Number of digital inputs: | 5 |
Supports protocol for BACnet: | no |